CS8900A-IQ Cirrus Logic Inc, CS8900A-IQ Datasheet - Page 20

no-image

CS8900A-IQ

Manufacturer Part Number
CS8900A-IQ
Description
Ethernet ICs IC 10Mbps Ethernet Controller 5V
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS8900A-IQ

Ethernet Connection Type
10Base- 2, 10Base- 5, 10Base- F, 10Base- T
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Product
Ethernet Controllers
Standard Supported
IEEE 802.3
Data Rate
10 Mbps
Maximum Operating Temperature
+ 85 C
Package / Case
LQFP-100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS8900A-IQ3
Manufacturer:
CIRRUS
Quantity:
44
Part Number:
CS8900A-IQ3
Manufacturer:
CRYSTAL
Quantity:
20 000
Part Number:
CS8900A-IQ3Z
Manufacturer:
Cirrus Logic Inc
Quantity:
1 852
Part Number:
CS8900A-IQ3Z
Manufacturer:
CIRRUS42
Quantity:
921
Part Number:
CS8900A-IQ3Z
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8900A-IQ3Z
Manufacturer:
CIRRUS
Quantity:
8 000
Part Number:
CS8900A-IQ3Z
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS8900A-IQ3Z
0
Part Number:
CS8900A-IQ3ZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8900A-IQ3ZR
0
Part Number:
CS8900A-IQFP
Manufacturer:
TI
Quantity:
2
Part Number:
CS8900A-IQZ
Manufacturer:
XILINX
Quantity:
912
Part Number:
CS8900A-IQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8900A-IQZ
Manufacturer:
CRYSTAL
Quantity:
20 000
Part Number:
CS8900A-IQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
3.3.2 Allowing Time for Reset Operation
After a reset, the CS8900A goes through a self
configuration. This includes calibrating on-chip
analog circuitry, and reading EEPROM for va-
lidity and configuration. Time required for the
reset calibration is typically 10 ms. Software
drivers should not access registers internal to
the CS8900A during this time. When calibra-
tion is done, bit INITD in the Self Status Regis-
ter (register 16) is set indicating that
initialization is complete, and the SIBUSY bit in
the same register is cleared indicating the EE-
PROM is no longer being read or pro-
grammed.
3.3.3 Bus Reset Considerations
After reset, the CS8900A packet page pointer
register (IObase+0Ah) is set to 3000h. The
3000h value can be used as part of the
CS8900A signature when the system scans
for the CS8900A. See Section 4.10 on
page 75.
After a reset, the ISA bus outputs INTRx and
DMARQx are 3-Stated, thus avoiding any in-
terrupt or DMA channel conflicts on the ISA
bus at power-up time.
3.3.4 Initialization
After each reset (except EEPROM Reset), the
CS8900A checks the sense of the EEDataIn
pin to see if an external EEPROM is present. If
EEDI is high, an EEPROM is present and the
CS8900A automatically loads the configura-
tion data stored in the EEPROM into its inter-
nal registers (see next section). If EEDI is low,
an EEPROM is not present and the CS8900A
comes out of reset with the default configura-
tion shown in Table 4.
A low-cost serial EEPROM can be used to
store configuration information that is automat-
ically loaded into the CS8900A after each re-
20
CIRRUS LOGIC PRODUCT DATASHEET
set (except EEPROM reset). The use of an
EEPROM is optional.
The CS8900A operates with any of six stan-
dard EEPROM’s shown in Table 5.
Crystal LAN™ Ethernet Controller
CS8900A
DS271F5

Related parts for CS8900A-IQ