COM20019ILJP SMSC, COM20019ILJP Datasheet - Page 34

no-image

COM20019ILJP

Manufacturer Part Number
COM20019ILJP
Description
Network Controller & Processor ICs ARCNET Contrllr
Manufacturer
SMSC
Datasheet

Specifications of COM20019ILJP

Product
Controller Area Network (CAN)
Number Of Transceivers
1
Data Rate
312.5 Kbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Supply Current (max)
20 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
PLCC-28
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rev. 11-07-08
4,3
2
1,0
7
6
5
4
BIT
BIT
Pulse1 Mode
Four NACKS
Reserved
Receive All
Extended
Timeout 1,2
Backplane
Sub Address 1,0
BIT NAME
BIT NAME
ET1, ET2
BACK-
PLANE
SUBAD
1,0
P1MODE
FOUR
NACKS
RCVALL
SYMBOL
SYMBOL
Table 6.10 - Setup 1 Register
These bits allow the network to operate over longer
distances than the default maximum 32 miles by controlling
the Response, Idle, and Reconfiguration Times. All nodes
should be configured with the same timeout values for
proper network operation. For the COM20019I 3V with a 20
MHz crystal oscillator, the bit combinations follow:
ET2
0
0
1
1
Note: These values are for 312.5 Kbps and
RCNTMR[1,0]=00. Reconfiguration time is changed by the
RCNTMR1 and RCNTMR0 bits.
A logic "1" on this bit puts the device into Backplane Mode
signaling which is used for Open Drain and Differential
Driver interfaces. This bit must be set to ‘1’ at the
COM20019I 3V.
These bits determine which register at address 07 may be
accessed. The combinations are as follows:
SUBAD1
See also the Sub Address Register.
DATASHEET
This bit determines the type of PULSE1 output driver used
in Backplane Mode. When high, a push/pull output is
used. When low, an open drain output is used. The
default is open drain.
This bit, when set, will cause the EXNACK bit in the
Diagnostic Status Register to set after four NACKs to Free
Buffer Enquiry are detected by the COM20019I 3V. This
bit, when reset, will set the EXNACK bit after 128 NACKs
to Free Buffer Enquiry. The default is 128.
Do not set. It must be 0.
This bit, when set, allows the COM20019I 3V to receive all
valid data packets on the network, regardless of their
destination ID. This mode can be used to implement a
network monitor with the transmitter on- or off-line. Note
that ACKs are only sent for packets received with a
destination ID equal to the COM20019I 3V's programmed
node ID. This feature can be used to put the COM20019I
3V in a 'listen-only' mode, where the transmitter is
disabled and the COM20019I 3V is not passing tokens.
Defaults low.
0
0
1
1
Page 34
Cost Competitive ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM
ET1
0
1
0
1
SUBAD0
0
1
0
1
DESCRIPTION
DESCRIPTION
Response
Time (mS)
9.548
4.774
2.387
0.597
Register
Tentative I
Node ID
Setup 1
Next ID
Idle Time
(mS)
10.496
5.248
2.624
0.656
SMSC COM20019I 3.3V Rev.C
Reconfig
Time (S)
13.44
13.44
13.44
6.72