COM20019I3V-HT SMSC, COM20019I3V-HT Datasheet - Page 35

no-image

COM20019I3V-HT

Manufacturer Part Number
COM20019I3V-HT
Description
Network Controller & Processor ICs ARCNET Contrllr
Manufacturer
SMSC
Datasheet

Specifications of COM20019I3V-HT

Product
Controller Area Network (CAN)
Number Of Transceivers
1
Data Rate
312.5 Kbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Supply Current (max)
25 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFP-48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
COM20019I3V-HT
Manufacturer:
Microchip Technology
Quantity:
10 000
SMSC COM20019I 3.3V
Cost Competitive ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM
3,2,1 Clock Prescaler
0
7
6,5,4
3
2
1,0
BIT
BIT
Bits 3,2,1
Slow Arbitration
Select
Read Bus Timing
Select
Reserved
Enhanced
Functions
No Synchronous
Reconfiguration
Timer 1, 0
BIT NAME
BIT NAME
CKP3,2,1
SLOWARB
RBUSTMG This bit is used to Disable/Enable the High Speed CPU
EF
NOSYNC
RCNTM1,0 These bits are used to program the reconfiguration timer as
SYMBOL
SYMBOL
Table 6.11 - Setup 2 Register
DATASHEET
Read function for High Speed CPU bus support.
RBUSTMG=0: Disable (Default), RBUSTMG=1: Enable.
That is, if BUSTMG (pin 26: Only for TQFP package) = 1
and RBUSTMG = 1, High Speed CPU Read operations are
enabled.
It does not influence write operation. High speed CPU
Read operation is only for non-multiplexed bus.
These bits are undefined. They must be 0.
This bit is used to enable the new enhanced functions in the
COM20019I 3V. EF = 0: Disable (Default), EF = 1: Enable.
If EF = 0, the timing and function is the same as in the
COM20020, Revision B. See appendix “A”. EF bit must be
‘1’ if the data rate is over 5Mbps.
EF bit should be ‘1’ for new design customers.
EF bit should be ‘0’ for replacement customers.
This bit is used to enable the SYNC command during
initialization. NOSYNC= 0, Enable (Default) The line must
be idle for the RAM initialization sequence to be written.
NOSYNC= 1, Disable:) The line does not have to be idle for
the RAM initialization sequence to be written. See appendix
“A”.
a function of maximum node count. These bits set the time
out period of the reconfiguration timer as shown below. The
time out periods shown are for 312.5 Kbps.
RCNTM1
0
0
1
1
Note*: The node ID value 255 must exist in the network for
420 mS timeout to be valid.
These bits are used to determine the data rate of the
COM20019I 3V. The following table is for a 20 MHz
crystal:
CKP3
0
1
Note: The lowest data rate achievable by the COM20019I
3V is 156.25 Kbs. Defaults to 011 or 312.5 Kbps.
This bit, when set, will divide the arbitration clock by 2.
Memory cycle times will increase when slow arbitration is
selected.
Defaults to low.
Page 35
CKP2
1
0
RCNTM0
0
1
0
1
CKP1
1
0
DESCRIPTION
DESCRIPTION
Time Out
Period
6.72 S
1.68 S
840 mS
420 mS*
DIVISOR
64
128
SPEED
312.5 Kbs
156.25 Kbs
Max Node Count
Up to 255 nodes
Up to 64 nodes
Up to 32 nodes
Up to 16 nodes
Rev. 11-07-08

Related parts for COM20019I3V-HT