Specifications of DS26504LN

Product
Framer
Number Of Transceivers
1
Data Rate
44.736 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
150 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
LQFP-64

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26504LN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS26504LN+T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS26504LNB2+
Manufacturer:
Maxim Integrated
Quantity:
10 000
9. E1 FRAMER/FORMATTER CONTROL REGISTERS
The E1 framer portion of the DS26504 is configured via a set of two control registers. Typically, the
control registers are only accessed when the system is first powered up. Once the DS26504 has been
initialized, the control registers only need to be accessed when there is a change in the system
configuration. There is one receive control register (E1RCR) and one transmit control register (E1TCR).
There are also two information registers and a status register, as well as an interrupt mask register. Each
of these registers is described in this section.
9.1 E1 Control Registers
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
HW
Mode
Bit 0: Resync (RESYNC). When toggled from low to high, a resync is initiated. Must be cleared and set again for a
subsequent resync.
Bit 1: Sync Enable (SYNCE)
Bit 2: Frame Resync Criterion (FRC)
Bits 3, 4, 7: Unused, must be set = 0 for proper operation.
Bit 5: Receive HDB3 Enable (RHDB3)
Bit 6: Receive Loss-of-Signal Alternate Criterion (RLOSA). Defines the criterion for a Receive Loss-of-Signal condition.
0 = auto resync enabled
1 = auto resync disabled
0 = resync if FAS received in error three consecutive times
1 = resync if FAS or bit 2 of non-FAS is received in error three consecutive times
0 = HDB3 disabled
1 = HDB3 enabled
0 = RLOS declared upon 255 consecutive zeros (125µs)
1 = RLOS declared upon 2048 consecutive zeros (1ms)
7
0
0
RLOSA
E1RCR
E1 Receive Control Register
1Dh
6
0
0
RHDB3
PIN 55
HBE
5
0
4
0
0
46 of 129
3
0
0
FRC
2
0
0
SYNCE
1
0
0
RESYNC
0
0
0