MAX194ACWE Maxim Integrated Products, MAX194ACWE Datasheet - Page 23

no-image

MAX194ACWE

Manufacturer Part Number
MAX194ACWE
Description
Audio A/D Converter ICs
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX194ACWE

Conversion Rate
85 KSPs
Resolution
14 bit
Number Of Adc Inputs
1
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX194ACWE
Manufacturer:
MAXIM/美信
Quantity:
20 000
measure of the ADC’s usefulness. Figure 26 shows the
effective number of bits as a function of the MAX194’s
input frequency calculated from the SINAD.
Figure 24. Circuit to Stop Free-Running Asynchronous CLK
Figure 25. MAX194 FFT Plot
(CLOCK SHUTDOWN)
-110
-130
-150
-10
-30
-50
-70
-90
0
(2 x CLK)
(CLK)
5
CK
Q
J
14-Bit, 85ksps ADC with 10µA Shutdown
______________________________________________________________________________________
10
CLOCK SHUTDOWN
15
FREQUENCY (kHz)
20
+5V
2 x CLK
25
30
J
K
CK
35
f
f
T
IN
S
1 / 2 74HC73
A
= 85kHz
= 1kHz
= +25°C
40
Q
If a pure sine wave is input to an ADC, AC integral non-
linearity (INL) of an ADC’s transfer function results in
harmonics of the input frequency being present in the
sampled output data.
Total Harmonic Distortion (THD) is the ratio of the RMS
sum of all the harmonics (in the frequency band above
DC and below one-half the sample rate, but not includ-
ing the DC component) to the RMS amplitude of the
fundamental frequency. This is expressed as follows:
where V
through V
harmonics. The THD specification in the Electrical
Characteristics includes the 2nd through 5th harmon-
ics. In the MAX194, this distortion is caused primarily
by the changes in on-resistance of the AIN sampling
switches with changing input voltage. These resistance
changes, together with the DAC’s capacitance (which
can also vary with input voltage), cause a varying time
delay for AC signals, which causes significant distortion
at moderately high frequencies (Figure 27).
THD = 20log——————————————
CLK
BP/UP/SHDN
1
MAX194
N
is the fundamental RMS amplitude, and V
are the amplitudes of the 2nd through Nth
(V
2
Total Harmonic Distortion
2
+ V
3
2
+ V
V1
4
2
+ ... + V
N
2
)
23
2