E5-648-C2421 EATON CUTLER HAMMER, E5-648-C2421 Datasheet - Page 4

no-image

E5-648-C2421

Manufacturer Part Number
E5-648-C2421
Description
PRESET COUNTER, 6-DIGIT, 90VAC TO 260VAC
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-648-C2421

No. Of Digits / Alpha
6
Digit Height
9mm
Supply Voltage Range
90VAC To 260VAC
Power Consumption
750VA
Counting Speed
50kHz
Operating Temperature Range
-20°C To +65°C
Instruction leaflet IL05407002E
Effective October 2010
4. Display/operating elements
Key
T1-6
P
R
8
9
10
11
12
Pr
5. inputs
5.1 INP A, INP B
5.2 Reset
5.3 Gate
4
Signal inputs: function acc. to operating mode
Max. frequency 60 kHz, can be damped in the programming
menu to 30 Hz
Pulse counter: count inputs
Frequency meter: frequency inputs
Timer: start input or start/stop inputs
Dynamic reset input: resets the pulse counter or timer to zero
(adding mode) or to preset value 2 (subtracting mode). The
reset input can be inhibited in the programming menu
Pulse counter: RESET input
Frequency meter: no function
Timer: RESET input
Static gate input: function depending on operating mode
Pulse counter: no counting while active
Frequency meter: no counting while active
Timer: no time measurement while active (Gate.hi);
no time measurement while not active (Gate.Lo)
Function
Decade key T1–T6
Prog/Mode key
Reset key
Current count value/main counter
Preset value/Total count/Batch counter
Run display for timer
Shows which preset value is being displayed
Shows which preset output is active
Keys necessary for programming the parameters (highlighted in grey)
eaton corporation www.eaton.com
For safety switching the relay outputs can be inverted,
i.e. the relay will be deenergized when the presets are reached.
To do this, the parameters Pr.OUT1 and Pr.OUT2 must be set to
5.4 Lock Input
5.5 MPI
6. outputs
6.1 Output 1
Relay with potential-free make (NO) contact
6.2 Output 2
Relay with potential-free make (NO) contact
6.3 Active Outputs
An active output will be shown on the display as
7. programming
7.1 Entering the program
7.2 Choice of main menus
7.3 Entering a sub-menu
Static keypad lock input for presets or programming. Lock-out
level can be set in the programming menu
Input. Programmable as Display Latch, Set or Teach-In input
(for permanent signal) or
Press the Reset key and Prog/Mode key
simultaneously for 3s
The security prompt appears in the display
Programming can be exited again using
the Prog/Mode key
Press key T2 to continue with the
programming
The security prompt appears in the display
Enter the main menu by pressing the
Prog/Mode key
The menus are selected using the
keys T2 (next) and T1 (back)
The sub-menu is opened with the
Prog/Mode key and the first menu item
is displayed
electronic preset counter
or
(for timed signal).
with two presets
E5-648-C242x
or
.

Related parts for E5-648-C2421