SI-LS42DMMHF BANNER ENGINEERING, SI-LS42DMMHF Datasheet - Page 8

no-image

SI-LS42DMMHF

Manufacturer Part Number
SI-LS42DMMHF
Description
SI-LS42DMMHF SAFETY INTERLOCK
Manufacturer
BANNER ENGINEERING
Type
Interlockr
Datasheet

Specifications of SI-LS42DMMHF

Actuator Type
Flexible
Body Style
Rectangular
Contact Form
! NC, ! NO
Current, Rating
4 AAC
Function
Safety
Ip Rating
IP67
Material, Contact
Silver-nickel alloy
Number Of Poles
2
Number Of Positions
2
Standards
UL Listed, CSA Certified, CE Marked
Temperature Rating
–30 TO +80 °C
Voltage, Rating
24 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Periodic checks should be performed only by Designated Persons or Qualified Persons,
as specified below. Safety switches should be checked at each shift change or machine
setup by a Designated Person (see below) for:
1. Breakage of the switch body or actuator,
2. Good alignment and full engagement of the actuator with the receptor,
3. Confirmation that the safety switch is not being used as an end stop,
4. Loosening of the switch or actuator mounting hardware, and
5. Verification that it is not possible to reach any hazard point through an opened guard
In addition, a Qualified Person should check for the following on a periodic schedule,
determined by the user, based upon the severity of the operating environment and the
frequency of switch actuations:
1. Check the wiring chamber for signs of contamination.
2. Check the contacts for signs of deterioration or damage.
3. Inspect the electrical wiring for continuity and damage.
4. Verify that wiring conforms to the instructions on pages 8 to 10 of this data sheet.
A Designated Person is identified in writing by the employer as being appropriately
trained to perform a specified checkout procedure. A Qualified Person possesses a
recognized degree or certificate or has extensive knowledge, training, and experience to
be able to solve problems relating to the safety switch installation (ANSI B30.2).
NOTE: Do not attempt any repairs to the switch. It contains no field-replaceable
If it ever becomes necessary to return a switch to the factory, please do the following:
1. Contact the Banner applications engineering department at the number or address
2. Pack the switch carefully. Damage which occurs in shipping is not covered by warranty.
Machine Safety Switches –
8
(or any opening) before hazardous machine motion has completely stopped.
listed on the front cover. They will attempt to troubleshoot the system from your
description of the problem. If they conclude that a component is defective, they will
issue an RMA (Return Merchandise Authorization) number for your paperwork, and
give you the proper shipping address.
P/N 60099 rev. D
components. Return the switch to the factory for warranty repair or replacement.