SI-LS42DMMHF BANNER ENGINEERING, SI-LS42DMMHF Datasheet - Page 6

no-image

SI-LS42DMMHF

Manufacturer Part Number
SI-LS42DMMHF
Description
SI-LS42DMMHF SAFETY INTERLOCK
Manufacturer
BANNER ENGINEERING
Type
Interlockr
Datasheet

Specifications of SI-LS42DMMHF

Actuator Type
Flexible
Body Style
Rectangular
Contact Form
! NC, ! NO
Current, Rating
4 AAC
Function
Safety
Ip Rating
IP67
Material, Contact
Silver-nickel alloy
Number Of Poles
2
Number Of Positions
2
Standards
UL Listed, CSA Certified, CE Marked
Temperature Rating
–30 TO +80 °C
Voltage, Rating
24 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Machine Safety Switches –
Access to Wiring Chamber
The wiring chamber is accessed via the hinged door. Simply insert a flat-blade
screwdriver, as shown in Figure 5, and pry gently down to open. Select the best wiring
entrance and thread in the ½" x 14 NPSM conduit adapter (supplied), or the optional M20
x 1.5 cable gland (page 12). The switch knockout will break loose with the final turn of
the conduit adapter or cable gland.
Figure . Access to wiring chamber – use a small flat-blade screwdriver
Figure . Connect two redundant safety switches per interlock guard to an appropriate

NOTE: Refer to the installation instructions provided with the safety module for information
P/N 60099 rev. D
To open wiring chamber:
1. Insert the screwdriver
blade into slot in cover to
pry cover open.
regarding the interface of the safety module to the machine stop control elements.
2-channel input safety module.
Solenoid
Monitor
Contact
Actuator
Safety
Contact
2-channel Gate Monitor Module, etc.)
Safety Switch #1
Electrical Installation
Channel
(2-channel E-stop Module
Input
2-channel Safety Module
#1
To connect wires to terminals:
1. Insert the screwdriver blade into the slot below the
2. Twist the screwdriver blade in the slot to open the
3. Hold wire in place and remove screwdriver.
Solenoid
Monitor
Contact
Actuator
Safety
Contact
desired wiring terminal.
terminal jaws; insert wire.
Safety Switch #2
Channel
Input
#2
SI-LS42 Series Locking Style Switch
Single gate
or guard
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
must be used for each interlock guard
to achieve control reliability or Safety
Category 4 (per ISO 1849-1, EN 94-1) of
a machine stop circuit. Use of only one
safety switch per interlock guard is not
recommended.
In addition, normally-closed safety contacts
from each of the two safety switches should
be connected to the two separate inputs of a
2-channel safety module or safety interface,
as illustrated in Figure 6. This is required to
provide monitoring for safety switch contact
failure, and to provide the necessary reset
routine, as required by IEC 60204-1 and
NFPA 79 machine safety standards.
Monitoring multiple guards with a series
connection of multiple safety interlock
switches is not a Safety Category 4
Application (per ISO 1849-1, EN 94-1).
A single failure may be masked or
not detected at all. When such a
configuration is used, procedures must
be performed regularly to verify proper
operation of each switch.
WARNING . . .
Connection of Safety
Interlock Switches
CAUTION . . .
Electrical Installation
Two safety switches
Series