ES-FA-6G BANNER ENGINEERING, ES-FA-6G Datasheet - Page 10

no-image

ES-FA-6G

Manufacturer Part Number
ES-FA-6G
Description
ES-FA-6G SINGLE OUTPUT E-STOP
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of ES-FA-6G

Relay Mounting
DIN Rail
Peak Reflow Compatible (260 C)
No
Coil Voltage Vdc Nom
24V
External Width
22.5mm
Contact Voltage Ac Nom
250V
External Depth
118.2mm
Coil Voltage Vac Nom
24V
Contact Current Max
6A
Contact Voltage Dc Nom
250V
External Height
82mm
E-Stop Safety Module
page
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Response Time
Input Requirements
Status Indicators
Housing
Mounting
Vibration Resistance
Operating Conditions
Dimensions
10
24V ac/dc, +/- 10%; 50/60Hz
Power consumption: approx. 2W/0.75VA
Protected against transient voltages and reverse polarity
Outputs (K1 & K2):
Contact ratings:
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors
across load. Never install suppressors across output contacts (see Warning, page 5).
35 milliseconds typical
E-stop switch must have a normally closed contact capable of switching 40 to 100mA @ 13 to 27V ac/dc.
Reset switch must have one normally open contact capable of switching 20 to 30mA @ 13 to 27V ac/dc.
3 green LED indicators:
Power ON
K1 energized
K2 energized
Polycarbonate. Rated NEMA 1; IEC IP40, Terminals IP20
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3
(IEC IP54), or better.
10 to 55Hz @ 0.35mm displacement per IEC 68-2-6
Temperature:
Maximum Relative Humidity: 90% @ +50°C (non-condensing)
See Figure 4.
Maximum voltage: 250V ac or 250V dc
Maximum current: 6 A ac or dc
Minimum current: 30 mA @ 10V dc
Maximum power: 1500VA, 150W
Mechanical life: 10,000,000 operations
Electrical life: 100,000 at full resistive load
E-Stop Safety Module Product Specifications
– Model ES-FA-6G
three redundant (total of six) safety relay (forced-guided) contacts – AgSnO
one auxiliary non-safety monitor output (open when both K1 and K2 are energized;
closed when either K1 or K2 are de-energized)
0° to +50°C (+32° to 122°F)
2