G32J-TA10 Omron, G32J-TA10 Datasheet - Page 3

no-image

G32J-TA10

Manufacturer Part Number
G32J-TA10
Description
ADAPTOR ROUND TERMINAL BLOCK
Manufacturer
Omron
Datasheet

Specifications of G32J-TA10

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G32JTA10
Specifications
■ Ratings and Characteristics
Ratings
Note: The load can be switched up to four times per hour. (Conditions: Rated current applied, Ambient temperature: 50°C max., Limit current:
G3JA Switching Frequency
G3JA-C
without fan)
Short Circuit Coordination (Maximum Fuse or Circuit Breaker Size) Type 1
Main Circuit
Item
Rated operating current
Heat dissipation, continuous
Rated operating voltage of main circuit 200 to 480 VAC (±10%), 50/60 Hz (±5%), 3-phase
Main circuit power
supply terminals
(L1, L2, and L3)
Main circuit load
power terminals
(T1, T2, and T3)
Control terminals
(A1, A2, IN1, IN2,
97, 98, 13, and 14)
Overload current range
Control voltage
Item
UL Class K5 and RK5 fuse
UL-listed combination (600 V)
UL-listed thermal electromagnetic circuit breaker
UL-listed combination (600 V)
Item
Rated operating voltage
Isolation rated voltage
Dielectric strength (between the
control and main circuits)
Repetitive peak voltage
Operating frequency
Utilization category
Single-phase/3-phase
Rated impulse voltage
DV/DT protection
Overvoltage category
60
50
40
30
20
10
0
300%, Start time: 15 s, ON time ratio: 70% max.) By using optional fans, however, it is possible to switch the load up to ten times per hour
under the same conditions.
5
(40°C, Start time: 10 s, Current limit: 350%
10
15
Wire gauge
Tightening torque 2.3 to 3.4 N·m
Wire gauge
Tightening torque 2.3 to 3.4 N·m
Wire gauge
Tightening torque 0.5 to 0.9 N·m
20
G3JA-C403/C409
G3JA-C416/C419
G3JA-C425/C430/C437
Classification
25
Load current (A)
30
Model G3JA-C403
35
200 to 480 VAC
600 VAC
2,200 VAC
1,400 V
50/60 Hz (±5%)
Intermittent duty
Equipment designed for 3-phase only
6 kV
1,000 V/μs
III
40
3 A
11 W
2.5 to 25 mm
2.5 to 16 mm
0.2 to 2.5 mm
1 to 3 A
100 to 240 VAC or 24 VAC, 50/60 Hz, 24 VDC
Model G3JA-C403 G3JA-C409 G3JA-C416 G3JA-C419 G3JA-C425 G3JA-C430 G3JA-C437
Rated breaking current: 5 kA
12 A
Rated breaking current: 5 kA
12 A
G3JA-C
with fan used)
2
2
2
9 A
12 W
3 to 9 A
(14 to 4 AWG), Stripping length (recommended): 11 mm
(14 to 6 AWG), Stripping length (recommended): 11 mm
G3JA-C409
(24 to 14 AWG), Stripping length (recommended): 9 mm
140
120
100
80
60
40
20
cULus (UL 508)
0
5
(40°C, Start time: 10 s, Current limit: 350%
30 A
30 A
10
16 A
14 W
5.3 to 16 A
G3JA-C416
15
20
G3JA-C403/C409
G3JA-C416/C419
G3JA-C425/C430/C437
60 A
60 A
25
19 A
15 W
6.3 to 19 A
G3JA-C419
Load current (A)
30
70 A
70 A
35
400 VAC
500 VAC
2,500 VAC
AC-53b
40
25 A
17 W
8.3 to 25 A
G3JA-C425
100 A
100 A
IEC (EN/IEC 60947-4-2)
30 A
19 W
10 to 30 A
G3JA-C430
110 A
110 A
G3JA-C
37 A
24 W
12.3 to 37 A
G3JA-C437
125 A
125 A
3

Related parts for G32J-TA10