P7SA-10F Omron, P7SA-10F Datasheet - Page 5

Contact OSTI For Purchase

P7SA-10F

Manufacturer Part Number
P7SA-10F
Description
Contact OSTI For Purchase
Manufacturer
Omron
Series
G7SAr
Type
Socketr
Datasheets

Specifications of P7SA-10F

Number Of Positions
10
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Associated Relay Series
G7SA
Number Of Poles
4
Accessory Type
Sockets
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G7SA Series
For Use With
Z2943 - RELAY SAFETY PCB 3PST-NO/1NC 24V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
P7SA10F
Z2947

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P7SA-10F
Manufacturer:
Omron Electronics Inc-EMC Div
Quantity:
135
Certified Standards
G7SA
Back-mounting Socket (for PCB)
P7SA-10P
Back-mounting Socket (for PCB)
P7SA-14P
• EN Standards, VDE Certified
• UL standard UL508 Industrial Control Devices
• CSA standard CSA C22.2 No. 14 Industrial Control Devices
EN61810-1 (Electromechanical non-specified time all-or-nothing
relays)
EN50205 (Relays with forcibly guided (linked) contacts)
0.5
(11.1)
4.1
24.8
60 max.
0.5
(11.1)
49.9
4.1
0.4
24.8
50 max.
(11.1)
39.9
15 max.
Three, 2.6 dia.
(for M3 tapping screws)
0.5
41.5 max.
3.5
0.4
(11.1)
15 max.
Three, 2.6 dia.
(for M3 tapping screws)
0.5
41.5 max.
3.5
G7SA-5A1B Mounted
G7SA-4A2B Mounted
G7SA-3A3B Mounted
Terminal Arrangement/Internal
Connection Diagram
(Bottom View)
0
1
0
1
0
1
Terminal Arrangement/Internal
Connection Diagram
(Bottom View)
11
23
21
21
11
11
12
G7SA-3A1B Mounted
24
12
22
12
22
G7SA-2A2B Mounted
0
1
0
1
33
43
33
43
31
43
34
44
34
44
32
44
Forcibly Guided Contacts
If an NO contact becomes welded, all NC contacts will maintain a
minimum distance of 0.5 mm when the coil is not energized. Likewise
if an NC contact becomes welded, all NO contacts will maintain a
minimum distance of 0.5 mm when the coil is energized.
11
23
21
11
53
63
53
63
53
63
12
24
12
22
54
54
54
64
64
64
33
43
33
43
34
44
34
44
Note: Terminals 23-24, 33-34, 43-44,
Mounting Hole Placement
(Bottom View)
(±0.1 tolerance)
Mounting Hole Placement
(Bottom View)
(±0.1 tolerance)
53-54, and 63-64 are normally
open. Terminals 11-12, 21-22,
and 31-32 are normally closed.
Note: Terminals 23-24, 33-34, and 43-44
are normally open. Terminals 11-12
and 21-22 are normally closed.
Fourteen,
1.1 dia.
Three, 3.2 dia.
(for M3 tapping
screws)
Ten, 1.1 dia.
Three, 3.2 dia.
(for M3 tapping screws)
(from EN50205)
G7SA
5

Related parts for P7SA-10F