NSH5-232UL-3M Omron, NSH5-232UL-3M Datasheet - Page 89

no-image

NSH5-232UL-3M

Manufacturer Part Number
NSH5-232UL-3M
Description
3m RS232 Cable For NSH5
Manufacturer
Omron
Datasheet

Specifications of NSH5-232UL-3M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
General Specifications
Note
Rated power supply voltage
Allowable power supply voltage range 20.4 to 27.6 VDC (24 VDC
Power consumption
Ambient operating temperature
(See note 1.)
Ambient storage temperature
(See note 1.)
Ambient operating humidity
Ambient operating environment
Noise resistance
Vibration resistance (during operation) 10 to 57 Hz with double amplitude of 0.075 mm, 57 to 150 Hz with acceleration of
Shock resistance (during operation)
Drop test (See note 2.)
External dimensions
Weight
Enclosure rating (See note 3.)
Ground
Battery life
Applicable standards
(1) Use the PT within the ambient operating and storage temperature ranges shown below.
(2) Conformance is evaluated under applicable test conditions, and it may not be possible to use the
(3) Conformance is evaluated under applicable test conditions, and it may not be possible to use the
PT in every environment.
PT in every environment. When used over a long period of time, the drip-proof packing may become
damaged or dirty and lose its effectiveness.
Item
Temperature (°C)
General Specifications
24 VDC
10 W max.
0 to 40
−20 to 60
35% to 85% max. (with no condensation)
No corrosive gases
Conforming to IEC 61000-4-4: 2 kV (power supply line)
9.8 m/s
147 m/s
Dropped from 1 m. Conforming to JIS B 3502/IEC61131-2.
223 × 179 × 70.5 mm (W × L × H)
1.1 kg max.
IP65
100
Battery life: 5 years (25
Low battery: Replace within five days of the indicator turning orange. SRAM, RTC
backup possible.
The SRAM and RTC can be backed up by a super capacitor for five minutes after
the old battery is removed (after the power has been turned ON for five minutes).
EC Directives and
°
or less
2
Appendix A
C
2
thirty minutes each in X, Y, and Z directions
°
three times each in X, Y, and Z directions
C
UL508
°
C)
±
15%)
Specifications
Storage
Operation
67