K3TE-V114 Omron, K3TE-V114 Datasheet - Page 6

no-image

K3TE-V114

Manufacturer Part Number
K3TE-V114
Description
PANEL METER DC INPUTS
Manufacturer
Omron
Series
K3TEr
Type
Voltmeterr
Datasheet

Specifications of K3TE-V114

Measuring Range
0 ~ 199.9mV
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
4
Display Digits - Height
0.559" (14.20mm)
Backlight
Without
Mounting Type
Panel Mount
Voltage - Supply
100 ~ 120VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Termination
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
K3TEV114
Safety Precautions
Mounting
Recommended panel thickness is 1 to 3.2 mm.
When mounting, insert the Digital Panel Meter in the mounting hole
and make sure that the Digital Panel Meter is secured with mounting
hooks.
Always attach the Mounting Bracket before wiring the terminals. Also,
always remove the wiring before removing the Mounting Bracket.
Mount the Digital Panel Meter as horizontally as possible.
Never use the Digital Panel Meter in locations where corrosive gas
(particularly sulfide or ammonia gas) is generated.
As much as possible avoid use of the Digital Panel Meter in a loca-
tion subject to severe shock or vibration, excessive dust, or exces-
sive moisture.
Select a mounting location where the Digital Panel Meter can be
used at an ambient operating temperature −10° to 55°C.
No product is shipped with the unit label attached. Select a unit label
from the sheet provided, and attach it to the Digital Panel Meter.
Calibration
Calibrate the Digital Panel Meter regularly so that the Digital Panel
Meter can maintain processing accuracy.
Use a standard signal generator with an accuracy of 99.99% min. for
calibration.
For the precise calibration methods, refer to the Instruction Sheet for
the Digital Panel Meter.
After the front panel cover is removed to calibrate the K3TE, be sure
not to touch components other than the calibration adjustor. Keep
metal objects off the K3TE while calibrating, especially when power
is turned on.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
http://www.ia.omron.com/
In the interest of product improvement, specifications are subject to change without notice.
Accessories (Order Separately)
Water-resistive Soft Front Cover
Before mounting the Digital Panel Meter to a panel, attach the water-
resistive soft front cover and mounting bracket to the Digital Panel
Meter properly so that the Digital Panel Meter will maintain IP51
water-resistive standards. Before you calibrate Digital Panel Meters,
remove the water-resistive soft front cover. Refer to the operation
manual included with the Digital Panel Meter for the calibration pro-
cedure.
Note: Be sure to use the Water-resistive Soft Front Cover and
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Soft Cover
mounting bracket together.
Mounting
Bracket
K3TE
6