Omron
Series
K3TEr
Type
Voltmeterr
Datasheet

Specifications of K3TE-V114

Measuring Range
0 ~ 199.9mV
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
4
Display Digits - Height
0.559" (14.20mm)
Backlight
Without
Mounting Type
Panel Mount
Voltage - Supply
100 ~ 120VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Termination
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
K3TEV114
Specifications
■ Ratings
Note: 1. An inrush current of approximately 0.5 A will flow at the moment the power is turned on and continued for approximately 2 ms.
■ Characteristics
Note: IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive
Supply voltage
Operating voltage range
Power consumption
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Ambient operating atmosphere
EMC
Approved standards
Input signal
A/D conversion method
Sampling period
Display refresh period
Max. displayed digits
Display
Decimal point display position
Sign display
Overflow/underflow display
Zero suppression
External control
Degree of protection
2. The K3TE-V4@@ does not conform to CE marking standards.
accessories.
http://www.ia.omron.com/
100 to 120 VAC; 200 to 240 VAC (50/60 Hz); 24 VDC (internally insulated)
−15% to +10% of supply voltage
3 VA (at max. AC load); 1.3 W (at max. DC load) (see note)
10 MΩ min. (at 500 VDC) between external terminal and case
AC model:
DC model:
AC/DC model: 2,000 VAC min. for 1 min between external terminal and case
AC model:
DC model:
Malfunction:
Destruction:
Malfunction:
Destruction:
Operating:
Storage:
Operating:
No corrosive gas
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Fast Transient Noise:
Immunity Burst Noise:
Immunity Surge:
Immunity Conducted Disturbance EN61000-4-6:
Immunity Voltage Dip/Interrupting EN61000-4-11:
Conforms to EN61326+A1, EN61010-1 (IEC61010-1)
Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted.
DC voltage/current
Double integral method
2.5 times/s
2.5 times/s
3 1/2 digits (±1999)
7-segment red LED
By short-circuiting terminals
“−” is displayed automatically with a negative input signal
Overflow:
Underflow: −1@@@
Not supported.
Process value hold (terminals on rear panel short-circuited)
Front panel: IEC IP51 (see note)
Case:
Terminals:
1@@@
IEC IP20
IEC IP00
−10° to 55°C (with no icing)
−20° to 65°C (with no icing)
35% to 85% (with no condensation)
2,000 VAC min. for 1 min between input terminal and power supply
500 VDC min. for 1 min between input terminal and power supply
±1,500 V on power supply terminals in normal or common mode
±480 V on power supply terminals in normal mode
±1,500 V on power supply terminals in common mode
10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions
10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
98 m/s
294 m/s
2
2
for 3 times each in 6 directions
for 3 times each in 6 directions
EN61326+A1
CISPR 11 Group 1 class A: CISRP16-1/-2
CISPR 11 Group 1 class A: CISRP16-1/-2
EN61326+A1
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Industry
Industry
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3)
2 kV (power line) (level 3)
1 kV line to line (I/O signal line)
1 kV line to line
2 kV line to ground (power line)
3 V (0.15 to 80 MHz) (level 2)
0.5 cycles, 0, 180°, 100% (rated voltage)
K3TE