Specifications of H3AM-NS-B AC100-240

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3AM-NS-BAC100-240
H3AMNSBAC100240
■ Characteristics
Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.
Accuracy of operating time ±0.7% FS max.
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage 3 kV between power terminals
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
Motor life expectancy
EMC
Enclosure rating
Weight
The H3AM-NS@-@-300 model with waterproof packing is available.
http://www.ia.omron.com/
±2% FS max.
Power reset:
Reset input time: 0.5 s max.
±1% FS max.
±2% FS max.
100 MΩ max. (at 500 VDC)
2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts
2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals
1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)
1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other
2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles
4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts
±1.5 kV (between power terminals) square-wave noise by a noise simulator
(pulse width: 100 ns/1 μs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Destruction: 300 m/s
Malfunction: 150 m/s
Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)
Electrical:
20,000 h
(EMI):
Emission Enclosure:
Emission AC Mains:
(EMS):
Immunity ESD:
Immunity RF-interference:
Immunity Power Frequency Magnetic Fields: IEC61000-4-8: 30 A/m (50 Hz)
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
IP65 (front panel only) (See note.) IP20 (terminal section)
Approx. 350 g
100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)
0.5 s max.
2
2
3 times each in 6 directions
(100 m/s
2
in the front/back direction) 3 times each in 6 directions
EN61812-1
EN55011 class A
EN55011 class A
EN61812-1
IEC61000-4-2: 6 kV contact discharge
IEC61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
IEC61000-4-6: 10 V (0.15 to 80 MHz)
IEC61000-4-4: 2 kV power-line
IEC61000-4-5: 1 kV line to line
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
8 kV air discharge
10 V/m (Pulse-modulated, 900 MHz±5 MHz)
2 kV I/O signal-line
2 kV line to ground
H3AM