G7S-3A3B-E DC24 Omron, G7S-3A3B-E DC24 Datasheet

no-image

G7S-3A3B-E DC24

Manufacturer Part Number
G7S-3A3B-E DC24
Description
Safety Relay,3PST-NO,3PST-NC
Manufacturer
Omron
Datasheet

Specifications of G7S-3A3B-E DC24

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Relays Conforming to EN Standard
Model Number Structure
Model Number Legend
1. NO Contact Poles
2. NC Contact Poles
Ordering Information
Relays with Forcibly Guided Contacts
Sockets
G7S-@A@B
• Relays with forcibly guided contacts
• Supports the CE marking of machinery (Machinery
• Helps avoid hazardous machine status when used as
• Track-mounting and Back-mounting Sockets are
Track-mounting
Back-mounting
Relays with Forcibly Guided Contacts
G7S
(EN50205 Class A, certified by VDE).
Directive).
part of an interlocking circuit.
available.
4: 4PST-NO
3: 3PST-NO
2: DPST-NC
3: 3PST-NC
Be sure to read the “Safety Precautions” on page 5 and the
“Precautions for All Relays with Forcibly Guided Contacts”.
1
Standard
Type
2
Common for track mounting and screw mounting
PCB terminals
6 poles
Poles
Type
Contact configuration
4PST-NO, DPST-NC
3PST-NO, 3PST-NC
Rated voltage
Rated voltage
24 VDC
24 VDC
---
CSM_G7S_DS_E_5_1
P7S-14F-END
P7S-14P-E
G7S-4A2B
G7S-3A3B
Model
Model
1

Related parts for G7S-3A3B-E DC24

G7S-3A3B-E DC24 Summary of contents

Page 1

... Relays with Forcibly Guided Contacts Type Poles Standard 6 poles Sockets Type Track-mounting Common for track mounting and screw mounting Back-mounting PCB terminals Contact configuration Rated voltage 4PST-NO, DPST-NC 24 VDC 3PST-NO, 3PST-NC Rated voltage 24 VDC --- CSM_G7S_DS_E_5_1 Model G7S-4A2B G7S-3A3B Model P7S-14F-END P7S-14P-E 1 ...

Page 2

... Approx G7S Max. voltage Power consumption (V) (W) 110% Approx. 0.8 Inductive load (cos φ = 0.4, L ms) ...

Page 3

... Relays with Forcibly Guided Contacts G7S-4A2B G7S-3A3B 62 max Terminal Arrangement/Internal Connection Diagram (Bottom View) 22.5 max. G7S-4A2B VDC max. 0.5 10.8 G7S-3A3B 5 min. 1 VDC 14 G7S (Unit: mm) Mounting Hole Dimensions 8 ± ± 14.5 0.1 0.1 ± 7 0.1 Fourteen, 1.8 dia. 21 ± 0 ± 6 0.1 3 ...

Page 4

... Two, 6.5 dia x 8 depth 6 5×7=35 Fourteen, M3.0 × 7.5 3.1 5.9 90.5 max. Terminal Arrangement/Internal Connection Diagram (Bottom View) With G7S-4A2B mounted With G7S-3A3B mounted 57 max. 13.2 4 (15) 16.9 14.5 23.5 max. Terminal Arrangement/Internal Connection Diagram (Top View) ...

Page 5

... Unit for an application example of the G7S. • Wire the terminals correctly with no mistakes in coil polarity, otherwise the G7S will not operate. Cleaning The G7S is not of enclosed construction. Therefore, do not wash the G7S with water or detergent. Forcibly Guided Contacts contact becomes welded, all NC contacts will maintain a minimum distance of 0 ...

Page 6

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords