G3MC-101P-VD DC12 Omron, G3MC-101P-VD DC12 Datasheet

no-image

G3MC-101P-VD DC12

Manufacturer Part Number
G3MC-101P-VD DC12
Description
SOLID STATE RELAY
Manufacturer
Omron
Series
G3MCr

Specifications of G3MC-101P-VD DC12

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
1A
Voltage - Input
9.6 ~ 14.4VDC
Voltage - Load
75 ~ 132 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
4-SIP
Input Type
DC
Input Voltage (max)
14.4V
Output Voltage (max)
132V
Output Current
1A
Isolation Voltage
2.5kV
Package Type
SIP
Output Device
Triac
Pin Count
4
Mounting
Through Hole
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3MC-101P-VDDC12
G3MC101PVDDC12
Compact, Thin-profile, Low-cost SSR
Switching 1 A (PCB-mounting)
Note: Refer to Precautions on page 229.
Ordering Information
Note: When ordering models conforming to VDE(basic insulation), add “-VD” to the model number. Reinforced insulation models are also
Phototriac
Isolation
Small bottom surface area (approx. 80% of the
conventional G3MB’s) and ideal for close PCB
mounting.
DC input and AC output for an applicable load of 1 A
at 40 C.
Compact, thin-profile SSR of monoblock construc-
tion with an all-in-one frame incorporates a PCB,
terminals, and heat sink.
Approved by UL and CSA.
Conforms to VDE.
Solid-state Relay
available. For details, contact your OMRON representative.
Yes
No
Yes
No
Yes
No
Zero-cross
function
No
Indicator
Yes
Snubber
circuit
1 A at 100 to 120 VAC
1 A at 100 to 240 VAC
2 A at 100 to 240 VAC
Applicable output
load
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
Rated input
voltage
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)
G3MC-201PL(-VD)
G3MC-202P(-VD)
G3MC-202PL(-VD)
G3MC
Model
RCW
225

Related parts for G3MC-101P-VD DC12

G3MC-101P-VD DC12 Summary of contents

Page 1

... Yes 100 to 120 VAC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 100 to 240 VAC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC 100 to 240 VAC 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC G3MC RCW Rated input Model voltage G3MC-101P(-VD) G3MC-101PL(-VD) G3MC-201P(-VD) G3MC-201PL(-VD) G3MC-202P(-VD) G3MC-202PL(-VD) 225 ...

Page 2

... VDC max. Applicable load Load voltage 75 to 132 VAC 50/ 264 VAC 50/ 264 VAC 50/60 Hz G3MC-101PL G3MC-201P (-VD) (-VD max. 1/2 of load power source cycle + 1 ms 1.5 mA max. (at 200 VAC) 2 – 100 C (with no icing or condensation) G3MC Voltage levels Must dropout voltage 1 VDC min ...

Page 3

... Ambient temperature ( C) Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the read value if it occurs repeatedly.) G3MC-202P(L) Energizing time (ms) Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the read value if it occurs repeatedly.) G3MC-101P(L), G3MC-201P(L) Energizing time (ms) G3MC 227 ...

Page 4

... G3MC PCB Dimensions (Bottom View) Four, 1.0-dia. holes Terminal Arrangement (Bottom View) PCB Dimensions (Bottom View) Four, 1.0-dia. holes 10 Terminal Arrangement (Bottom View) ...

Page 5

... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J108-E1-1B Fusing characteristics The G3MC has a function that forces an open mode failure when an overcurrent exceeds the rated value. The fusing characteristics of the G3MC, however, are not the same as those of a general-use glass fuse ...

Related keywords