D4NS-SK01 Omron, D4NS-SK01 Datasheet - Page 9

no-image

D4NS-SK01

Manufacturer Part Number
D4NS-SK01
Description
Safety Door Switch
Manufacturer
Omron
Series
D4NSr
Datasheet

Specifications of D4NS-SK01

Lead Free Status / Rohs Status
 Details
Safety Precautions
Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches”.
Incorrect operation may cause injury. Also, the product is
designed to be mounted so that it slides horizontally.
Do not mount the product in a vertically sliding
configuration.
(excluding the D4NS-SK01)
• Do not drop the Switch. Doing so may prevent the Switch from
• Mount the Switch securely to prevent it from falling. Otherwise,
• Do not attempt to disassemble or modify the Switch. Doing so may
• Make sure that the gap between the shot bolt and guide is ±3 mm.
• To ensure safety, do not operate the Switch with anything other
• Be careful to avoid pinching your hand when operating the Switch.
• Be sure to mount the Switch protective cover. Otherwise, your
• When opening the door, be sure to lower the disable-prevention
• The durability of the Switch is greatly influenced by the switching
• The user must not maintain or repair equipment incorporating the
• Refer to the D4JL Guard Lock Safety-door Switch, D4NS
• Do not shut the door while the shot bolt is extended. The Switch
• Do not apply excessive force in the direction of the slide. This may
functioning to full capacity.
injuries may occur.
cause the Switch to malfunction.
Otherwise, excessive wear or damage may cause malfunction.
than a Slide Key.
hand may be injured by being pinched between the shot bolt and
Switch when closing the door with your hand on the Switch.
cover into position, attach a padlock, or take other steps to prevent
other people from operating the Switch.
conditions. Always test the Switch under actual working conditions
before application and use it in a switching circuit for which there
are no problems with performance.
Switch. Contact the manufacturer of the equipment for any
maintenance or repairs required.
Safety-door Switch Datasheet, Instruction Sheet for details and
handling information on the Switch.
may be damaged, preventing proper operation.
damage the product and cause it to malfunction.
Precautions for Safe Use
!CAUTION
Appropriate Tightening Torque
Technical Specifications
• Insert the slide handle until the red operation indicator is
• Loose screws may result in malfunction. Use washers and tighten
• Use the D4NS-SK30 only with the D4NS Safety-door Switch head
• Do not store the Switch where corrosive gases (e.g., H
• Perform maintenance inspections periodically.
• This product is for use only with OMRON Safety-door Switches.
Slide Key mounting screw (M6)
Switch mounting screw
(included with product)
Switch protective cover mounting screw
(included with product)
Lever mounting screw
(included with product)
Ambient operating
temperature
Ambient operating
humidity
Mechanical
durability
Weight
completely displayed in the operation display window.
the screws to the specified torques. Also, when mounting the
Switch to a door for disable-prevention purposes, purchase and
use tamper-resistant screws.
in the direction shown below.
NH
high temperature or humidity.
Do not use it with door switches made by other manufacturers.
3
, HNO
3
, or Cl
Precautions for Correct Use
Normal
2
) or dust are present, or in locations subject to
Operation display window
−10 to 55°C (with no icing)
95% max.
20,000 operations min.
Approx. 3.4 kg
(not including D4JL
Guard Lock Safety-door
Switch)
D4JL-SK40
Insufficient insertion
For D4JL
For D4NS
D4NS-SK/D4JL-SK
Operation Key
6.0 to 7.0 N·m
3.2 to 3.8 N·m
0.5 to 0.7 N·m
1.2 to 1.4 N·m
1.2 to 1.4 N·m
Approx. 2.8 kg
(not including D4NS
Safety-door Switch)
D4NS-SK30
2
S, SO
2
,
9

Related parts for D4NS-SK01