CS1W-CLK53 Omron, CS1W-CLK53 Datasheet - Page 12

no-image

CS1W-CLK53

Manufacturer Part Number
CS1W-CLK53
Description
Controller Link Mod GI Optical
Manufacturer
Omron
Datasheet

Specifications of CS1W-CLK53

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Differences in Specifications of New and Old Models
The following table shows the main differences in specifications between the new and old models.
Number of data link send words
(data link areas that are created for
a single node in a single PLC)
Number of send words per node
(total of area 1 and area 2)
Data link areas
Max. Units mountable per PLC
Automatic data link setting
Changing data link allocations
during active data links
Maximum connectable nodes
Duplex support
Mixed use
Compatible support software
Note:
1. For wired models, the maximum number of nodes is 32 if Repeater Units are not used.
2. Use models with lot numbers 0306@@ (June 2003 production) or later to enable duplexing in a CS1D System using the Pre-Ver. 1.2 CS1W-CLK12-V1 or
3. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models.
The following table shows the main differences in specifications between the new and old models of Controller Link Support Boards.
Number of data link send/receive
words
(data link areas for
sending/receiving that are created
for a single node in a single
computer)
Send words per node
Changing data link allocations
during active data links
Maximum connectable nodes
Mixed use
Compatible FinsGateway and
version of supplied CD
(See note 3.)
Compatible support software
Note:
1. For wired models, the maximum number of nodes is 32 if repeater units are not used.
2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models.
3. FinsGateway Version 2003 is compatible with Windows XP and Windows 2000. For Windows NT4.0 (Service Pack 3 or higher), Windows ME, or Windows
Usage Precautions
CS1W-CLK52-V1.
The data link send/receive words can be separately set to their maximums when new and old models are mixed.
The data link send/receive words can be separately set to their maximums when new and old models are mixed.
98SE, use FinsGateway Version3. (With FinsGateway Version 3, only functions supported by the 3G8F7-CLK21/CLK12/CLK52 can be used.)
・ Old models and new models can be used mixed on the same network. In that case, however, build the system using the
・ Repeater Units can be used to expand a Wired Controller Link Network. For Wired-to-optical Repeater Units, always use a set of
・ Connect Repeater Units so that there are no more than two stages between any two nodes. One set of two Wire-to-Optical
specifications for the old models. The data link send/receive words can be separately set to their maximums when new and old
models are mixed.
two (1:1). Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units.
Repeater Units is counted as one stage.
Model
Model
20,000 words max.
4,000 words max.
Allocation setting can be performed for same areas in areas 1 and 2.
8
Choose from equality layout or 1:N allocations (common type, 1:1, chain type)
Supported (Data link tables can be changed during active data links.)
62 nodes (See note 1.)
Supported (optical ring model only) (See note 2.)
Yes (See note 3.)
CX-Integrator for CX-One V2.1or
62,000 words max.
4,000 words max. (user-set links only)
Supported. (Data link tables can be changed during active data links.)
62 nodes (See note 1.)
Yes (See note 2.)
FinsGateway Version 2003.21 or higher
CX-Integrator for CX-One Ver. 2.1 or
(user-set links only)
higher, or CX-Net for
CX-Programmer Ver. 7.2 or
higher
(CD Ver. 3.00 or higher)
higher , or CX-Net for CX-Programmer Ver.
7.2 or higher
Unit version 2.0
CS1W-CLK23
CS1W-CLK13
CS1W-CLK53
3G8F7-CLK23-E
3G8F7-CLK13-E
3G8F7-CLK53-E
1,000 words max.
CX-Net for CX-Programmer Ver.
5.0 or higher
CS1W-CLK21-V1
CS1W-CLK12-V1
CS1W-CLK52-V1
Unit version 1.2
1,000 words max.
FinsGateway Version 2003.00 or higher
(CD Ver. 2.00 or higher)
CX-Net for CX-Programmer Ver. 3.2 or
higher
3G8F7-CLK21-EV1
3G8F7-CLK12-EV1
3G8F7-CLK52-EV1
12,000 words max.
Allocation setting can be performed for same areas in areas 1 and 2.
4
CX-Net for CX-Programmer Ver.
3.2 or higher
Note: The following models
CS1W-CLK21-V1
CS1W-CLK12-V1
CS1W-CLK52-V1
are discontinued.
Pre-Ver. 1.2
FinsGateway Version 3.00 or higher
(CD Ver. 1.00 or higher)
CX-Net for Ver. 1.0 or higher
32,000 words max.
Not supported.
Wired model: 32 nodes
Optical ring model: 62 nodes
Note: The following models are
Supported for equality layout
Not supported.
Wired model: 32 nodes
Optical ring model: 62 nodes
Not supported
only.
CX-Net for CX-Programmer Ver.
1.0 or higher
3G8F7-CLK21-E
3G8F7-CLK12-E
3G8F7-CLK52-E
Note: The following models
discontinued.
are discontinued.
CS1W-CLK21
CS1W-CLK12
CS1W-CLK52
Pre-Ver. 1.2
12