E2C-ED02 Omron, E2C-ED02 Datasheet - Page 4

Shld 8mm Smart Box

E2C-ED02

Manufacturer Part Number
E2C-ED02
Description
Shld 8mm Smart Box
Manufacturer
Omron
Datasheets

Specifications of E2C-ED02

Maximum Operating Temperature
+ 60 C
Supply Voltage
12 V to 24 V
Mounting Style
DIN Rail
Sensing Distance
2 mm
Minimum Operating Temperature
- 10 C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Amplifier Units
* Communications are disabled if the detection mode is selected during super-high-speed sensing mode, and the communications functions for
Item
Supply voltage
Power consumption
Control output
Response
time
Functions
Digital display
Display orientation
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Material
mutual interference prevention and the Mobile Console will not function.
Model
Super-high-
speed mode
High-speed
mode
Standard mode
High-resolution
mode
Differential
detection
Timer function
Zero-reset
Initial reset
Mutual interfer-
ence prevention
Hysteresis
settings
I/O settings
Case
Cover
NPN output
PNP output
Type
*
12 to 24 VDC ±10%, ripple (p-p): 10% max.
1,080 mW max. (current consumption: 45 mA at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector output; load current: 50 mA max.
(residual voltage: 1 V max.)
150 μs for operation and reset respectively
300 μs for operation and reset respectively
1 ms for operation and reset respectively
4 ms for operation and reset respectively
Switchable between single edge and double edge detection mode
Single edge: Can be set to 300 μs, 500 μs, 1 ms, 10 ms, or 100 ms
Double edge: Can be set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Negative values can be displayed. (Threshold is not shifted.)
Settings can be returned to defaults as required.
Possible for up to 5 Units.
Intermittent oscillation method (Response time = (number of Units connected + 1) ×15 ms)
Setting range: 10 to 4,000
Output setting (Select from channel 2 output, area
output, self-diagnosis, or open circuit detection.)
Select from the following: Incident level + threshold, incident level percentage +threshold, incident light peak
level + incident light bottom level (updated with output), long bar display, incident level + peak hold, incident
level + channel
Switching between normal/reversed display is possible.
Operating:
Storage: –20°C to 70°C (with no icing)
Operating/storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 min
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC60529 IP50
Prewired
Approx. 100 g
PBT (polybutylene terephthalate)
Polycarbonate
When used in combination with an EDR6-F
E2C-EDA11
E2C-EDA41
Advanced Models with Twin Outputs
When connecting 1 to 2 Units: –10°C to 55°C
When connecting 3 to 5 Units: –10°C to 50°C
When connecting 6 to 16 Units: –10°C to 45°C
When connecting 3 to 4 Units: –10°C to 50°C
When connecting 5 to 8 Units: –10°C to 45°C
When connecting 9 to 16 Units: –10°C to 40°C
2
for 3 times each in X, Y, and Z directions
*
Connector
Approx. 55 g
E2C-EDA6
E2C-EDA8
Approx. 100 g
Input setting (Select from teaching, fine positioning,
zero-reset, synchronous detection.)
Prewired
Advanced Models with External Inputs
E2C-EDA21
E2C-EDA51
Connector
Approx. 55 g
E2C-EDA7
E2C-EDA9
E2C-EDA
4