Lead free / RoHS Compliant
Setting ON/OFF Angles Using Support
Software
With 16-/32-output models, programs can be uploaded or
downloaded easily with the optional Support Software (H8PS-SOFT-
V1) by connecting a personal computer to the Cam Positioner using
the USB cable (Recommended USB Cables: ELECOM CO.Ltd.
U2C-MF20BK).
Support Software Functions
• Writing cam programs
• Setting functions
• Editing, saving, and printing programs
• Displaying and printing cam program operation charts
• Simple simulations of programs
Refer to the user’s manual for the Support Software for details.
Applicable OS: Windows 98, 2000, ME, or XP
Checking Timing (Test Mode)
Testing Operation
Operation can be tested to check operation timing.
Note: 1. Outputs will turn ON and OFF in Test Mode. Confirm system
• Set the mode switch to TEST.
• If the timing is not correct, change the ON/OFF angle settings.
• Operate the Encoder and check the timing of operation.
The settings can be changed in Test Mode.
CAM
1
2
2. With 16-/32-output model, be sure to turn ON the start input.
PRGM
TEST
RUN
safety before switching to Test Mode.
Outputs are not turned ON unless the start input is turned
ON.
Mode
STEP
7
TST
Present angular position
ON/OFF angle setting
H8PS
23