Y92F-91 Omron, Y92F-91 Datasheet
Y92F-91
Specifications of Y92F-91
Related parts for Y92F-91
Y92F-91 Summary of contents
Page 1
Cam Positioner H8PS This Compact Cam Positioner, Popular for Its Ease-of-use, Now Comes with Even Better Functions. • Compact 8-, 16-, and 32-output Models available that are 1/4- DIN size mm. • High-speed operation at 1,600 ...
Page 2
... E6C3-AG5C-C 256 2M E6C3-AG5C-C 360 2M E6C3-AG5C-C 720 2M E6F-AG5C-C 256 2M E6F-AG5C-C 360 2M E6F-AG5C-C 720 2M Specification Model Y92S-41-200 E5ZE-CBL200 H8PS-SOFT-V1 E69-C06B E69-C08B E69-C10B E69-DF5 Y92C-30 Y92A-96B Y92A-96N Y92F-91 7 PFP-50N 7 PFP-100N PFP-100N2 PFP-M PFP-S Recommended manufacturer Specification A-miniB, 2m H8PS 4. Output configuration None: NPN transistor output ...
Page 3
Specifications ■ Ratings Item H8PS-@B Rated supply voltage 24 VDC Operating voltage range 85% to 110% of rated supply voltage Mounting method Flush mounting Power consumption Approx. 4 26.4 VDC for 8-output models Approx. 6 26.4 ...
Page 4
Characteristics Setting unit 0.5 increments at a resolution of 720, 1 increments at a resolution of 256 or 360 (See note 1.) Number of steps steps can be set for each cam to turn the output ...
Page 5
... Displays both the present angular position and the number of Encoder revolutions (speed) in Run Mode. speed displays Switches back and forth between the main display showing the present angular position with the sub-display showing the speed and the main display showing the speed with the sub-display showing the present angular position ...
Page 6
Connections ■ Terminal Arrangement H8PS-8@ (8-output Models) NPN Output, Encoder Flush Mounting H8PS-8@ Alignment markings (Rear view NPN Output, Encoder Surface Mounting H8PS-8@F Alignment markings 9 10 ...
Page 7
... E5ZE-CBL200 Connector-type Output Cable (Order Separately) Connections H8PS-16@/-32@ E5ZE-CBL200 Connector-type Output Cable (Order Separately) (CN1) (CN2) Output Output Cable 1 Cable 2 XG4M-2030 MIL Connector (made by OMRON) Output Cable 1 Wiring Table Outputs Connector Outputs Connector pin No. pin No. Cam 1 20 Cam 9 19 Cam 2 18 ...
Page 8
Using Connector-Terminal Block Conversion Units H8PS-16@/-32@ E5ZE-CBL200 Connector-type Output Cable (Order Separately) (CN1) (CN2) Output Cable 1 Output Cable 2 XW2D-20G6 Connector-Terminal Block Conversion Unit (Order Separately) 2. Y92S-41-200 Discrete Wire Output Cable (Order Separately) Connections H8PS-16@/-32@ Y92S-41-200 Discrete Wire ...
Page 9
Input Connections Only the Encoder inputs are connected with 8-output Models. The inputs are no-voltage (short-circuit or open) inputs. No-voltage Inputs Contact Input Open Collector PLC, sensor, etc. H8PS-16 H8PS-32@ Note: Operates when ...
Page 10
Operating Mode ■ Functions The H8PS Cam Positioner receives angle signal inputs from the Dedicated Absolute Encoder and outputs the preset ON/OFF angles as cam outputs. Program Examples 1. H8PS-8@ (8-output Models) Cam output Step 0 (cam number) ON angle ...
Page 11
... CLEAR key Programming Mode: Press and hold at least shift to the Function 10. ORIGIN key Run Mode: Press and hold at least enable/disable the All Protection 12 Switches modes. Programming Mode (PRGM): CHECK 1. CHECK key Test Mode (TEST): Used to modify settings while the Encoder is running. ...
Page 12
... Track Mounting Mounting 74.4 60.6 (See note 1.) DIN Track DIN Track Mounting Base Y92F- (Order Separately) Note: 1. These dimensions vary with the kind of DIN track (reference value 8-output Model is shown in the above diagrams. The Encoder is connected from the bottom with 16-/ 32-output Models ...
Page 13
Encoder Connecting Direction H8PS-8B@ H8PS-8BF@ Encoder ■ Accessories (Order Separately) Parallel Input Adapters Y92C-30 This Adapter enables two H8PS Cam Positioners to share signals from an Encoder. Note: H8PS has been improved in 2004 April. Do not mix old and ...
Page 14
... The numbers in parentheses () are dimensions for the PFP-50N. End Plate PFP pan-head screw 50 11 spring washer 131.7 115.6 29.4 DIN Track Mounting Base Y92F-91 Connector-type Output Cable E5ZE-CBL200 Cable length PFP-100N2 7.3± 0.15 4.5 35± 27± 0.3 0. ...
Page 15
E6CP-A/E6C3-A/E6F-A Rotary Encoders (Absolute) • Combining this Encoder with an H8PS Cam Positioner enables high-precision detection of the operation timing of various automatic machines. • The E6CP low-cost, money-saving Encoder. • The standard E6C3-A is well suited to ...
Page 16
Dimensions Note: All units are in millimeters unless otherwise indicated. E6CP-AG5C-C Note: Order the E69-C06B Coupling separately. Accessory Mounting Bracket (Included) 2 5.5 dia. holes (18 +0.1 8 3.1 0 Two (5.1) E6C3-AG5C-C D cut: Phase-Z ...
Page 17
Accessories (Order Separately) E69-C06B Shaft Coupling (for the E6CP) 22 5.5 5.5 (11) Four, M3 Hexagon 2.8 socket-head setscrews 2.8 (16.4) 6H8 dia.15 dia. Note: The material is fiber-glass-reinforced polybutylene terephthalate resin (PBT). E69-DF5 Extension Cable 16.9 dia. Note: Refer ...
Page 18
Safety Precautions for Cam Positioners Refer to Safety Precautions for All Counters. !CAUTION Tighten terminal screws to a torque of 0.80 N·m so that they do not become loose. Minor fires or malfunction may occasionally occur. For 16- and 32-output ...
Page 19
Precautions for Correct Use • A cam output will remain ON if the set angles for two steps overlap for the same cam number. Step 1: 120 ON 170 OFF Step 2: 150 ON 210 OFF ON OFF 120 ...
Page 20
... Key ON/OFF ADV 5 s min min. All Protection Switching the Angle and Speed Display Disables all keys Main Display: Angle and switches. Sub-display: Speed will light when the all protection function is Main Display: Speed enabled. ➾ Sub-display: Angle Refer to page 24. ➾ ...
Page 21
Setting Resolution and Rotation Direction One of three resolutions can be selected for the Encoder connected to the H8PS: 256, 360, or 720. The resolution and display angle are set here. Turn OFF the power supply. Set the display angle ...
Page 22
Setting ON/OFF Angles in Manual Mode ON/OFF angles can be set manually using the ANGLE Keys on the front of the Cam Positioner. Example: Setting Step 1 of Cam No Turn and Turn OFF at ...
Page 23
Setting ON/OFF Angles Using Support Software With 16-/32-output models, programs can be uploaded or downloaded easily with the optional Support Software (H8PS-SOFT- V1) by connecting a personal computer to the Cam Positioner using the USB cable (Recommended USB Cables: ELECOM ...
Page 24
... Key is pressed for at least ADV Run Mode, the All Protection indicator will light on the display and all keys and switches will be disabled. If the mode switch is changed to Programming or Test Mode while protection is enabled, the All Protection indicator will flash to indicate that settings cannot be changed ...
Page 25
Clearing Settings Clearing All Programs The all clear function can be used to delete all cam programs, the settings for advance angle compensation function, and all other settings. All settings in the Function Setting Mode will be returned to their ...
Page 26
... RUN ADV Key 5 s min. ON/OFF Key 1 s min. All Protection Switching the Angle and Speed Display Disables all keys Main Display: Angle and switches. Sub-display: Speed will light when the all protection function is Main Display: Speed enabled. ➾ Sub-display: Angle Refer to page 24. ➾ ...
Page 27
Advance Angle Compensation (ADV) Function The advance angle compensation function automatically advances the ON/OFF angle of cam outputs in proportion to machine (encoder) speed. As the speed of the machine increases, the system can be affected by the delay in ...
Page 28
Pulse Output (f1/f2) Outputs a preset number of pulses per Encoder rotation. Pulses are output at a 1:1 ON/OFF ratio and pulse output can be started from a specified angle. Operation for 9 Output Pulses and a Start Angle of ...
Page 29
Step Number Limit (f5) With the H8PS steps can be set to turn the output ON/OFF 10 times for each cam. The number of steps that can be set, however, can be restricted to prevent programming from ...
Page 30
Bank Switching Method (f8) The following methods can be used to switch the bank: the bank inputs on the terminal block or the BANK Key on the front of the Cam Positioner. The method is set using the F8 menu ...
Page 31
Self Diagnostic Function The following displays will appear on the main display if an error occurs error occurs, all outputs (including cam, pulse, and run outputs) will be turned OFF. Display Meaning e00 Origin designation data error ...
Page 32
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...