G2A-432A-DC24 Omron, G2A-432A-DC24 Datasheet - Page 3

RELAY

G2A-432A-DC24

Manufacturer Part Number
G2A-432A-DC24
Description
RELAY
Manufacturer
Omron
Series
G2Ar
Datasheets

Specifications of G2A-432A-DC24

Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
0.5A @ 24VDC
Coil Type
Standard
Coil Current
45mA
Coil Voltage
24VDC
Control On Voltage (max)
19.2 VDC
Control Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Socketable
Coil Voltage Vdc Nom
24V
Contact Current Max
500mA
Contact Voltage Ac Nom
110V
Contact Voltage Dc Nom
24V
Coil Resistance
530ohm
Contact Configuration
4PDT
Contact Form
SPST - NO
Contact Rating
1 A
Contact Termination
PCB
Mounting Style
Solder / Plug-In
Power Consumption
33 mW
Contact Material
Gold Overlay Silver Palladium
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2A432ADC24
■ Contact Ratings
■ Characteristics
Note: 1. The data shown above are initial values.
■ Approved by Standards
UL508 (File No. E41515)
Load
Contact type
Contact material
Rated load
Rated carry current
Max. switching power
Contact resistance
(see note 2)
Operate time (see note 3)
Release time (see note 3)
Max. operating frequency
Insulation resistance
(see note 4)
Dielectric strength
Vibration resistance
Shock resistance
Error rate (level P)
(Reference value)
(see note 6)
Endurance
Ambient temperature
Ambient humidity
Weight
G2A-@-US
2. The contact resistance was measured with 0.1 A at 5 VDC using the voltage drop method.
3. The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute.
of 23°C.
strength.
Classification
Model
http://www.ia.omron.com/
6 to 120 VAC
6 to 120 VDC
Crossbar bifurcated
Movable:
Fixed:
0.3 A at 110 VAC
0.5 A at 24 VDC
3 A
250 VAC, 125 VDC
100 mΩ max.
15 ms max.
15 ms max.
Mechanical: 18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load)
100 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min between coil and contacts and contacts of different polarities (700 VAC be-
tween contacts of same polarity)
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
1 mA at 100 mVDC
Mechanical:
Electrical:
Operating:–10°C to 40°C (with no icing or condensation)
Operating:5% to 85%
Approx. 38 g
Standard/Acr barrier equipped/Built-in operation
Coil ratings
indicator models (G2A-@-N)
AgAu-clad AgPd
AgPd
Resistive load (cosφ = 1)
100,000,000 operations min. (at operating frequency of 18,000 operations/hour)
5,000,000 operations min. (under rated load and at operating frequency of
1,800 operations/hour) (see note 5)
2
2
1 A 120 VAC (resistive load)
1 A 30 VDC (inductive load)
Contact ratings
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
0.2 A at 110 VAC
0.3 A at 24 VDC
Built-in diode/Built-in operation indicator models
30 ms max.
Inductive load (cosφ = 0.4) (L/R = 7 ms)
(G2A-@-N1)
G2A
3

Related parts for G2A-432A-DC24