G2A-432A-DC24 Omron, G2A-432A-DC24 Datasheet

RELAY

G2A-432A-DC24

Manufacturer Part Number
G2A-432A-DC24
Description
RELAY
Manufacturer
Omron
Series
G2Ar
Datasheets

Specifications of G2A-432A-DC24

Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
0.5A @ 24VDC
Coil Type
Standard
Coil Current
45mA
Coil Voltage
24VDC
Control On Voltage (max)
19.2 VDC
Control Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Socketable
Coil Voltage Vdc Nom
24V
Contact Current Max
500mA
Contact Voltage Ac Nom
110V
Contact Voltage Dc Nom
24V
Coil Resistance
530ohm
Contact Configuration
4PDT
Contact Form
SPST - NO
Contact Rating
1 A
Contact Termination
PCB
Mounting Style
Solder / Plug-In
Power Consumption
33 mW
Contact Material
Gold Overlay Silver Palladium
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2A432ADC24
Highly Reliable, 4-pole Miniature Relay Ideal
for Sequence Control
• Card lift-off employed for greater life and stable quality.
• Long endurance and stable quality are assured by card lift-off
• Mounting interchangeability with MY-series Relays.
• Operation indicator mechanism incorporated for at-a-glance
Ordering Information
Model Number Legend
1. Number of Poles and Contact Form
2. Contact Type
3. Enclosure Construction
4. Terminal Shape
Note: 1. The coil of the G2A-432A-N1 or a built-in diode model operates with DC only.
Note: 1. When placing your order, add the coil voltage rating listed in the specifications to the model number as shown below.
G2A-@@@@@-@
Standard model
Arc barrier equipped model
Built-in diode model
Built-in operation indicator model
Built-in operation indicator and diode model
UL-
approved
model
system.
monitoring of ON/OFF operation. In addition, a built-in operation
indicator model is also included in this Relay Series.
Power Relay
G2A
4:
3:
2:
A:
1P:
2. The G2A Series include the G2A-434A Power Relay and G2AK Latching Relay. Refer to page 133 for details.
3. Built-in indicator models satisfying international standards are available. Contact your OMRON representative for details.
2. Built-in diode model and the operating coil of the G2A-432A-N1 are available only with DC ratings.
3. The Latching Relay (G2AK) and Fully sealed Relay (G2A-434A) developed based on the G2A are also available in this se-
1
Example: G2A-432A 100/110 VAC
ries.
2
4PDT
Crossbar bifurcated
Casing
Plug-in
PCB
3 4
Standard model
Arc barrier equipped model
Classification
5
6
Rated coil voltage
G2A-432A
G2A-432AY
G2A-432A-D
G2A-432A-N
G2A-432A-N1
G2A-432A-US
G2A-432AY-US
Plug-in terminals/Solder terminals
5. Safety Breaking Mechanism
6. Special Element
None: No
Y:
None: Standard
D:
N:
N1:
US:
Arc barrier
Built-in diode
Built-in operation indicator
Built-in operation indicator and diode
UL-approved
G2A-4321P
---
G2A-4321P-D
---
---
G2A-4321P-US
---
Power Relay
PCB terminals
G2A
119

Related parts for G2A-432A-DC24

G2A-432A-DC24 Summary of contents

Page 1

... Note: 1. When placing your order, add the coil voltage rating listed in the specifications to the model number as shown below. Example: G2A-432A 100/110 VAC 2. Built-in diode model and the operating coil of the G2A-432A-N1 are available only with DC ratings. 3. The Latching Relay (G2AK) and Fully sealed Relay (G2A-434A) developed based on the G2A are also available in this se- ries. Model Number Legend ...

Page 2

... For built-in operation indicator models rated at 6, 12, and 24 VDC, add an LED current of approx the rated currents. G2A 120 Power Relay Built-in diode Built-in operation indicator G2A-432A-D G2A-432A-N The built-in operation indicator model has a newly added opera- tion indicator to the conventional operation indication mechanism and facilitates operation monitor- ing without being affected by am- bient illumination ...

Page 3

... Coil ratings G2A-@- 120 VAC 6 to 120 VDC Resistive load (cos = 1) AgAu-clad AgPd AgPd indicator models (G2A-@-N) max. min. (at 500 VDC 100,000,000 operations min. (at operating frequency of 18,000 operations/hour) 5,000,000 operations min. (under rated load and at operating frequency of 1,800 operations/hour) (see note 5) ...

Page 4

... Endurance 10,000 5,000 1,000 500 100 50 110-VAC inductive load 10 cos = 0.4 Ambient Temperature vs. Coil Temperature Rise G2A 110 VAC (50 Hz) Contact carry current Number of Relays: 5 Ambient temperature ( C) G2A DC Contact carry current Number of Relays: 5 Ambient temperature ( C) 24-VDC resistive load 24-VDC inductive load ...

Page 5

... Carry contact Break contact Make contact Self-holding contact 4 Operations ( Coil Self-load Life Curve (Unit: mA) Model Specifications 1 G2A-432A 100 VAC VDC 45 90 Relay Mounting Adjacent Distance vs. Coil Temperature Rise G2A-432A 24 VDC Relay mounting Upper position Condition: The saturated coil temperature is measured with rated coil voltage (24 VDC) imposed ...

Page 6

... Check terminal for operation monitoring Built-in operation monitoring lamp possible +0 77.5 0.4 2-dia. hole Shorting lead Three, 1.2-dia. holes With Back-connecting Socket G2A 45.5 PY14 Socket For Back-connecting Socket PYC-5 PCB terminals PY14-0 PY14-02 Panel Cutout +0 0.3 34.5 0.4 +0 ...

Page 7

... PCB Terminal Models 0.5 1 21.5 max. 2.6 0.5 28.5 max. 1.8 4 42.5 max. Arc Barrier Equipped Models 48, 100 VDC Mounting Holes on PCB (Bottom View) 5 Fourteen, 1.5-dia. holes 4.1 12.65 6.35 7.3 4.4 4.4 13.2 Built-in Diode Models G2A 125 Power Relay ...

Page 8

... ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. J014-E1-02 G2A 126 Power Relay PYP-18 (for Mounting 18 Sockets) 492 27 ...