Specifications
C200H/C200HS Specifications
Part number
Data memory
(DM) words
Program check
Power Supply Specifications
Part number
Supply voltage
Operating voltage
range
Power
consumption
Surge current
Output capacity
Fuse
Input power supply
Insulation
resistance*
Dielectric strength*
Noise immunity
Vibration**
Shock
Ambient
temperature
Humidity
Atmosphere
Grounding
Enclosure rating
Acceleration (G)
1
*Disconnect the LG terminal of the Power Supply Module from the GR terminal when performing insulation and dielectric strength
tests. If the tests are performed with the LG and GR terminals short-circuited, the internal components will be damaged. Do not
conduct a dielectric strength test on the C200H-CPU03-E, C200H-CPU23-E, C200H-PS211, C200H-RT002-P, or C200H-RT202
modules. The power supply input line and internal circuit of the 24 VDC power supply are not isolated from each other. If a dielec-
tric strength test is conducted, the power supply will be damaged.
10
57
Amplitude
Read/write: 1,000 (DM 0000 through 0999)
Read only: 1,000 (DM 1000 through 1999)
DM area as in Memory Park.
Program check (executed on start of RUN operation):
END missing, Instruction errors,
(Program can be checked by Programming Console, GPC, or LSS at three levels.)
100 to 120/200 to 240 VAC selectable, 50/60 Hz
85 to 132/170 to 264 VAC
100 VA max.
30 A max.
CPU01-E, 3 A, 5 VDC (1.6 A supplied to I/O Modules)
CPU-21-E: 4.6 A, 5 VDC (3.2 A supplied to I/O Modules)
CPU-31-E: 4.6 A, 5 VDC (3.0 A supplied to I/O Modules)
HS-CPU01-E, HS-CPU21-E, HS-CPU31-E 4.6 A, 5 VDC (3.9 A
supplied to I/O Modules)
Expansion I/O Rack: 3 A, 5 VDC (2.7 A supplied to I/O Modules)
2 A, 250 V, 5.2 dia. x 20 (MF51NR)
0.3 A, 24 VDC
20 MΩ between AC terminals and the GR terminal at 500 VDC
2,000 VAC, 50/60 Hz for 1 minute between AC terminals and housing
500 VAC, 50/60 Hz for 1 minute between DC terminals and housing.
Leakage current: 10 mA max.
1,500 Vp-p, pulse width: 100 ns to 1
Mechanical durability: 10 to 35 Hz, 1 mm double amplitude (2.5 G) in X, Y, and Z directions, for 2 hours each
(When mounted on DIN track, 16.7 Hz, 1 mm double amplitude (0.5 G) in X, Y, and Z directions, for 1 hour each)
Malfunction durability: 2 to 55 Hz, 2 G, in X, Y, and Z directions, for 20 minutes each (When mounted on DIN track,
2 to 55 Hz, 0.3 G, in X, Y, and Z directions, for 20 minutes each)
10 G in X, Y, and Z directions, 3 times each
Operating: 0° to 55°C (0° to 45°C for Programming Console)
Storage: -20° to 65°C
35% to 85% (without condensation)
Must be free of the following: Corrosive gases; Abrupt temperature changes; Direct sunlight; Dust, salt, or metal
filings; Water, oil, or chemicals
Less than 100 Ω
IEC IP30 (mounted in a panel)
C200H-CPU01-E/CPU03-E
C200H-CPU01-E/CPU21-E/CPU31-E, C200HS-CPU01-E,
150
C200HS-CPU21-E, C200HS-CPU31-E, C200H-PS221
Frequency (Hz)
+10%
/
-20%
CPUs
C200H-CPU21-E/CPU23-E

s, rise time: 1 ns (by noise simulator)
C200H-CPU31-E
24 VDC
20.4 to 26.4 VDC
50 W max.
30 A max.
CPU03-E: 3 A, 5 VDC (1.6 A supplied to I/O
Modules)
CPU-23-E: 3 A, 5 VDC (1.6 A supplied to I/O
Modules)
HS-CPU03-E, HS-CPU23-E, HS-CPU33-E:
3 A, 5 VDC (2.3 A supplied to I/O Modules)
Expansion I/O Rack: 3 A, 5 VDC (2.7 A
supplied to I/O Modules)
2 A, 125 V, 5.2 dia. x 20 (MF51NR)
C200HS-CPU23-E, C200HS-CPU33-E,
C200H-CPU23-E, C200HS-CPU03-E,
Read/Write: 6144 (DM0000
through 6143)
Read only: 512 (6144 through
6655)
3000 Word max. (DM7000
through 9999)
C200HS-CPU01-E/CPU03-E
C200HS-CPU21-E/CPU23-E
C200HS-CPU31-E/CPU33-E
C200H-PS211