Datasheet

Specifications of FLUKE-787

Includes
Battery, Clips, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD
Display Count
4000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
Q4953585
787
Users Manual
AC Current Measurement
DC Current Measurement
38
AC conversion: true rms
Maximum crest factor: 3
For non-sinusoidal waveforms, add (2% reading + 2% f.s.) typical
Overload protection 440 mA, 1000V fast-blow fuse
Note: 440 mA continuous, 1A 30 seconds maximum
Specifications are valid from 5% to 100% of amplitude range.
Note: 440 mA continuous, 1A 30 seconds maximum
Overload protection: 440 mA, 1000V fast-blow fuse
45 Hz to 2 kHz
1.000A (Note)
30.000 mA
1.000A (Note)
Range
Range
Resolution
Resolution
0.001A
0.001 mA
0.001A
Accuracy, (% of Reading + Counts)
Accuracy, (% of Reading + Counts)
1% + 2
0.05% + 2
0.2% + 2
Typical Burden
Typical Burden
1.5V/A
14 mV/mA
1.5V/A
Voltage
Voltage