FLUKE-787 Fluke Electronics, FLUKE-787 Datasheet - Page 41

no-image

FLUKE-787

Manufacturer Part Number
FLUKE-787
Description
PROCESS METER
Manufacturer
Fluke Electronics
Series
ProcessMeter™r
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-787

Includes
Battery, Clips, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD
Display Count
4000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
Q4953585
DC Millivolts Measurement
AC Volts Measurement
AC conversion: true rms
Maximum crest factor: 3
For non-sinusoidal waveforms, add (2% reading + 2% f.s.) typical
Input impedance: 10 M (nominal), < 100 pF, ac-coupled
Common mode rejection ratio: >60 dB at dc, 50 Hz, or 60 Hz
Specifications are valid from 5% to 100% of amplitude range.
Range (mV dc)
Range (ac)
400.0
400.0 mV
4.000V
40.00V
400.0V
1000V
Resolution
Resolution
0. 1 mV
0.1 mV
0.001V
0.01V
0.1V
1V
50 Hz to 60 Hz
0.7% + 4
0.7% + 2
0.7% + 2
0.7% + 2
0.7% + 2
Accuracy, (% of Reading + Counts)
Accuracy (% of Reading + Counts)
45 Hz to 200 Hz
0.1% + 1
1.2% + 4
1.2% + 4
1.2% + 4
1.2% + 4
1.2% + 4
200 Hz to 500 Hz
7.0% + 4
7.0% + 4
7.0% + 4
7.0% + 4
7.0% + 4
ProcessMeter
Specifications
37