FLUKE-177 ESFP Fluke Electronics, FLUKE-177 ESFP Datasheet - Page 2

DMM TRE RMS W/BCKLGT 6000CNT DIS

FLUKE-177 ESFP

Manufacturer Part Number
FLUKE-177 ESFP
Description
DMM TRE RMS W/BCKLGT 6000CNT DIS
Manufacturer
Fluke Electronics
Series
ToolPak™, 17xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-177 ESFP

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Vendor undefined / RoHS compliant by exemption
Other names
1564560
177 ESFP
614-1020
For detailed specifications contact your local Fluke representative, or visit www.fluke.com.
Specifications are subject to change without notice.
Features
6000 count display
Auto Hold and Manual Hold
IEC 1010 Rating: CAT IV 600V / CAT III 1000V
Backlight for measurements in low visibility environments
Temperature measurements in C and F, Thermocouple included
Battery door provides battery access without breaking the calibration seal
Compatible with Fluke ToolPak
Available Fluke Accessories
Meter Hanging
Cases
Test Leads
Current Clamp
Temperature
Specialty
Continuity
Temp
Hz
Range
Accuracy
Crest Factor
AC Response
Range
Accuracy
Range
Accuracy
AC Response
Range
Accuracy
Range
Best Accuracy
Range
Best Accuracy
Range
Accuracy
Range
Accuracy
meter hanging kit
1% of rdg + 3 counts
2% of rdg + 3 counts
Beeper guaranteed on <25 , guaranteed off >250 ;
detects opens or shorts of 250 s or longer
0.01 mA to 10.00A
0.01 mA to 10.00A
0.1
(20A overload for
(20A overload for
0.1 mV to 1000V
0.1 mV to 1000V
45 Hz to 500 Hz
500 Hz to 1 kHz
(0.15% of reading
1 nF to 9999 F
2 Hz to 100 kHz
Fluke 175
45 Hz to 1 kHz
45 Hz to 1 kHz
2 Hz to 30 kHz
(1.5% of reading
(1.0% of reading
(0.9% of reading
(1.2% of reading
(0.1% of reading
plus 3 counts)
plus 3 counts)
plus 2 counts)
plus 2 counts)
Voltage Input:
Current Input:
plus 1 count)
plus 1 count)
30 seconds)
30 seconds)
to 50.00 M
3
175, 177, 179
ToolPak magnet and strap kit
C510 leather meter case
C50 padded meter case
C20 hard meter case
All Fluke Test Leads
All Fluke Current Clamp Accessories
80TK Thermocouple Module
80T-150U Univ. Temperature Probe
80AK Thermocouple Adapter (179 only)
80T-IR/80PK-IR Temperature Probe
80K-6, 80K-40 High Voltage Probe
PV 350 Pressure Module
FOM Fiber Optic Meter
1% of rdg + 3 counts
2% of rdg + 3 counts
0.01 mA to 10.00A
0.01 mA to 10.00A
0.1
(20A overload for
(20A overload for
0.1 mV to 1000V
0.1 mV to 1000V
45 Hz to 500 Hz
500 Hz to 1 kHz
1 nF to 9999 F
2 Hz to 100 kHz
(0.09% of reading
(1.5% of reading
45 Hz to 1 kHz
(1.0% of reading
45 Hz to 1 kHz
(0.9% of reading
(1.2% of reading
2 Hz to 30 kHz
(0.1% of reading
Fluke 177
plus 3 counts)
plus 3 counts)
plus 2 counts)
plus 2 counts)
Voltage Input:
Current Input:
plus 1 count)
plus 1 count)
30 seconds)
30 seconds)
to 50.00 M
3
175
1% of rdg + 3 counts
2% of rdg + 3 counts
0.01 mA to 10.00A
0.01 mA to 10.00A
0.1
(20A overload for
(20A overload for
0.1 mV to 1000V
0.1 mV to 1000V
-40 C to +400 C,
177
45 Hz to 500 Hz
500 Hz to 1 kHz
1 nF to 9999 F
2 Hz to 100 kHz
-40 F to +752 F
Fluke 179
(0.09% of reading
(1.5% of reading
45 Hz to 1 kHz
(1.0% of reading
45 Hz to 1 kHz
(0.9% of reading
(1.2% of reading
2 Hz to 30 kHz
(0.1% of reading
plus 3 counts)
plus 3 counts)
plus 2 counts)
plus 2 counts)
Voltage Input:
Current Input:
plus 1 count)
plus 1 count)
30 seconds)
30 seconds)
C 1% + 10,
F 1% + 18
to 50.00 M
3
179
Ordering
Information
Fluke 175 Digital Multimeter
Fluke 177 Digital Multimeter
Fluke 179 Digital Multimeter
Need Technical Assistance? Call:
1-800-44-FLUKE
Toll-free in the U.S.
(800) 36-FLUKE in Canada
(425) 446-5500 other countries
For more information to be sent
to you by fax, call 1-800-FLUKE-FAX
in the U.S. and Canada. Or, visit our
Website at http://www.fluke.com
Fluke. Keeping your world
©2000 Fluke Corporation. All rights reserved.
10/2000 1593526 D-ENG-N Rev A
up and running.