FLUKE-177 ESFP Fluke Electronics, FLUKE-177 ESFP Datasheet - Page 14

DMM TRE RMS W/BCKLGT 6000CNT DIS

FLUKE-177 ESFP

Manufacturer Part Number
FLUKE-177 ESFP
Description
DMM TRE RMS W/BCKLGT 6000CNT DIS
Manufacturer
Fluke Electronics
Series
ToolPak™, 17xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-177 ESFP

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Vendor undefined / RoHS compliant by exemption
Other names
1564560
177 ESFP
614-1020
Models 175, 177 & 179
Users Manual
Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use
abrasives or solvents. Dirt or moisture in the terminals can affect
readings.
Testing the Fuses
Test fuses as shown below.
10
To avoid electrical shock or injury, remove the test
leads and any input signals before replacing the fuse.
HOLD
MIN MAX
RANGE
<12
V
X W
440 mA
Warning
OK
OK
<.5
11 A
AIK12F.EPS
OK
OK
Replacing the Battery and Fuses
F1 Fuse, 440 mA, 1000 V, FAST
F2 Fuse, 11 A, 1000 V, FAST
B1 Battery, 9 V Alkaline,
NEDA 1604 / 1604A
To avoid shock, injury, or damage to the Meter:
F1
Use ONLY fuses with the amperage, interrupt,
voltage, and speed ratings specified.
Replace the battery as soon as the low battery
indicator (
b
) appears.
XW
F2
Warning
Fluke PN 943121
Fluke PN 803293
Fluke PN 614487
B1
AIK13F.EPS
b