Datasheet

Specifications of N50P111

Output
Contactless Magnetic Switch
Switch Function
2 Axis with Select
Actuator Type
Joystick
Termination Style
SMD (SMT) Tab
Operating Force
70/180gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contact Rating @ Voltage
-
EasyPoint
Datasheet - X Y C o o r d i n a t e s I n t e r p r e t a t i o n
Knob on Position 2.
The center of the magnet has been moved upon the horizontal wakeup threshold Xp. The EasyPoint module sets INTn LOW (active). At this
point, the microcontroller can configure the module with INT_function (Reg 0Fh [2]) = 0 and change the Low Power timebase Reg 0Fh [6:4] for a
faster reaction time. In this interrupt mode, the interrupt output goes LOW (active) each time a new X and Y value is ready to be read by the
microcontroller. The interrupt is reseted HIGH (not active) once the register Y_res_int has been read
Knob on Position 3.
The magnet has been moved to the maximum distance from the center (+2.0mm). The maximum X value is -128 decimal.
9.1.1 Knob Displacement and Register Value Relation
Figure 7
0.0mm is the center of the module, when the knob is released).
The Y axis measurements are the same as the X axis ones. Positive X register values are the left side knob movements, positive Y register
values are the upper side knob movements.
Those values are in an ideal condition, where the knob takes place over the center position of the N50P111 sensor once released. The zero
position may vary between two N50 modules, and an offset must be applied to X and Y in order to compensate the X,Y coordinates to 0,0 once
the knob is released. More information can be found in chapters
Figure 7. X Register / X Displacement (Y=0µm)
www.austriamicrosystems.com/N50P111
shows the relation between the X register value and the physical X coordinate of the central knob (±2.0mm horizontal displacement,
Register X output
TM
N50P111
-2000
-1000
8.2
X - direction
and 8.3.
Revision 1.1
-128
127
-63
63
0
0
1000
(see I²C Registers on page
Mechanical Position (µm)
2000
23).
13 - 32