MTCBA-C1-EN2-N3-NAM Multi-Tech Systems, MTCBA-C1-EN2-N3-NAM Datasheet - Page 55

no-image

MTCBA-C1-EN2-N3-NAM

Manufacturer Part Number
MTCBA-C1-EN2-N3-NAM
Description
ROUTER WIRELESS DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® rCellr
Datasheets

Specifications of MTCBA-C1-EN2-N3-NAM

Function
Transceiver, CDMA, Router
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RJ-45, RS-232
Features
US Power Cord
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1067
Service Programming Code +WSPC
Description:
Syntax:
Values:
Excess SPC Failures +WLCK
Description:
Note:
Syntax:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
This command allows for entry of the service programming code (either MSL or OTKSL). Upon
successful entry of this code, all other service provisioning AT commands may be used. If this
code is not properly entered prior to attempting other provisioning AT commands, all provisioning
commands will return ERROR. If the OTKSL is used to enter provisioning mode, only the +WIMI,
+WMDN, and +WCMT commands will be allowed. All other commands will return ERROR.
Once the correct SPC code is entered, the modem transitions to the Service Programming state.
This state is not exited until a commit is done (+WCMT). While in the Service Programming state,
subsequent validations of the SPC code are ignored until the Service Programming state is reset.
Verizon requires the following additional action:
Command syntax: AT+WSPC=[<lock type>[,<code>]]
<lock type>
<code>
This response indicates that 15 failed attempts have been made to enter the service
programming code. If the modem is not in emergency mode, any active call will be terminated
and the modem will go into offline mode.
A successfully entered service programming code grants access to modem configuration data.
Response Syntax: +WLCK: “Excess SPC failures!”
Command
AT+WSPC?
Note: Service programming code request
AT+WSPC=?
AT+WSPC=1,111111
Note: Enter service programming code 111111
AT+WSPC=1,000000
Note: Enter service programming code 000000
Command
AT+WSPC=0,123456
Note: 15th attempt to enter the SPC.
0
1
If the SPC fails verification 15 consecutive times, the modem will provide an unsolicited
message indicating excessive SPC verification failures (see Excess SPC Failures +WLCK)
and then shutdown. This is in accordance to Verizon’s OTA specification. The host
application must prevent the modem from restarting for 1 minute when this condition occurs.
OTKSL – One Time Key Subsidy Lock
MSL – Master Subsidy Lock
Six character programming code.
Possible Responses
+WLCK: “Excess SPC failures!”
Note: Modem now in offline mode.
Chapter 11 – Provisioning Control Commands
Possible Responses
ERROR
Note: Invalid request
ERROR
Note: Invalid request
ERROR
Note: Code invalid
OK
Note: Code valid
55