Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RS-232, USB
Data Rate - Maximum
153.6kbps
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1100
Values:
Request PRL Version Information +WPRL
Description:
Syntax:
Note:
Update Authentication Key +WAKY
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
<nam>
<cur_seq>
<last seq>
<length>
<cr>
<PrlData>
This command requests PRL Version information for the currently selected NAM.
Command syntax: AT+WPRL?
The range for PRL is a 16-bit type.
This command sets the 20 character decimal A-Key in the modem. Do not include the 6 digit A-
Key checksum (digits 21 through 26) as these digits are ignored. When this command is issued,
the SDD data areas will be zeroed out. The A-Key value cannot be read back with the
AT+WAKY? Command.
Command Syntax: AT+WAKY=<nmbr>
<nmbr>
AT+DPRL=?
Note: Display parameter ranges.
AT+DPRL?
Note: Display last used parameter values.
Command
AT+WPRL?
Note: Request current NAM’s PRL version
AT+WPRL?
Note: Request current NAM’s PRL version
Command
AT+WAKY=12345678901234567890
Note: Set the A-Key
Sequence number of this PRL data packet. An error is returned if this value is
Sequence number of the last PRL data packet. The PRL is considered
NAM to receive the <PrlData>.
Note:
dependent and settable at the factory. When only a single NAM is allowed,
NAM1 is the only supported value.
greater than <last_seq> or is non-sequential with the previous <cur_seq> value.
When set to zero, the current internal buffer contents is discarded prior to
appending the <PrlData> bytes.
complete when <cur_seq> is equal to <last_seq>. If the +WCMT=1 command is
issued prior to <cur_seq> equal to <last_seq>, the downloaded PRL data will be
discarded.
Length of <PrlData> expressed as a decimal number.
Carriage return character. Value 13 decimal or 0x0d hexadecimal.
PRL binary data. Once <length> bytes have been received by the modem, the
OK response is returned.
A-Key number
Some modems are configured to support only a single NAM. This is carrier
Possible Responses
+WPRL: 1024
OK
+CME ERROR: 41
Note: PRL request invalid because there’s no
PRL loaded.
Possible Responses
OK
Note: A-Key successfully set.
+DPRL: (1-2),(0-255),(0-255),(1-16384)
OK
Note: Valid parameter ranges.
+DPRL: 1,0,0,57
OK
Note: Parameter values displayed.