MTCMR-C1-N3 Multi-Tech Systems, MTCMR-C1-N3 Datasheet - Page 113

no-image

MTCMR-C1-N3

Manufacturer Part Number
MTCMR-C1-N3
Description
MODEM CELLULAR DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® iCellr
Datasheets

Specifications of MTCMR-C1-N3

Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RS-232, USB
Data Rate - Maximum
153.6kbps
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1100
Configure Antenna Diagnostics Polling Interval
+WANTPOLL
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
Values:
This command is used to configure the interval between primary and/or secondary antenna
diagnostic checks. When the antenna status changes, the modem outputs a +WANTS message.
A change of status is defined as an antenna ADC reading which crosses into a different range
(OPEN/NORMAL/SHORT) as defined by the short and open limit settings using AT+WANTLIM
for the antenna. The modem may also be configured to generate a ring indication when the
antenna diagnostic status changes.
If periodic diagnostic checking of the antennas is not desired, the application can query the
antenna status by using the AT+WANTS command.
The antenna status check occurs every <interval> seconds. One unsolicited message is issued
on any status change for the requested antennas.
Command Syntax: AT+WANTPOLL=<action>[,<sel>,<interval>]
<action>
<sel>
<interval>
checking
checking parameters
Command
AT+WANTPOLL=1,1,30
Note: Check primary antenna diagnostic
status every 30 seconds
AT+WANTPOLL=1,3,120
Note: Check primary and secondary
antenna diagnostic status every 2 minutes
AT+WANTPOLL=0
Note: Disable periodic antenna diagnostic
AT+WANTPOLL?
Note: Display periodic antenna diagnostic
checking parameters
AT+WANTPOLL?
Note: Display periodic antenna diagnostic
<primaryAntStatus>
<secondaryAntStatus>
0
1
1
2
3
1-86400 Interval in seconds between antenna diagnostic checks
0
1
2
0
1
2
Enable periodic checking
Check periodically and report change only for primary antenna
Check periodically and report change only for secondary antenna
Check periodically and report change for primary and secondary antennas
Disable periodic checking
SHORTED (ADC value < low limit)
NORMAL ( low limit <= ADC value <= high limit)
OPEN (ADC value > high limit)
SHORTED (ADC value < low limit)
NORMAL ( low limit <= ADC value <= high limit)
OPEN (ADC value > high limit)
is disabled
Possible Responses
OK
OK
OK
+WANTPOLL: 1,1,30
OK
Note: Primary antenna diagnostic status is
checked every 30 seconds
+WANTPOLL: 0
OK
Note: Periodic antenna diagnostic checking
Chapter 19 – Antenna Commands