CRD-5378 Cirrus Logic Inc, CRD-5378 Datasheet - Page 25

no-image

CRD-5378

Manufacturer Part Number
CRD-5378
Description
Audio Modules & Development Tools Ref Bd LP Sngl-Ch Decimation Filter
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CRD-5378

Description/function
Audio D/A
Operating Supply Voltage
3.3 V
Product
Audio Modules
Supply Current
100 mA
For Use With/related Products
CS3302A, CS5373A, CS5378
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Telemetry signals enter CRD5378 through RS-485 transceivers, which are differential current mode
transceivers that can reliably drive long distance communication. Data passes through the RS-485 trans-
ceivers to the microcontroller I
2.3.3.1
Clock and synchronization telemetry signals into CRD5378 are received through RS-485 twisted pairs.
These signals are required to be distributed through the external system with minimal jitter and timing
skew, and so are normally driven through high-speed bus connections.
Synchronization of the measurement channel is critical to ensure simultaneous analog sampling across
a network. Several options are available for connecting a SYNC signal through the RS-485 telemetry to
the digital filter.
A direct connection is made when the SYNC_IO signal is received over the dedicated RS-485 twisted pair
and sent directly to the digital filter SYNC pin (with a 0 Ω resistor installed at R71). The incoming SYNC_IO
signal must be synchronized to the network at the transmitter since no local timing adjustment is available.
A microcontroller hardware connection is made when the SYNC_IO signal is received over the dedicated
RS-485 twisted pair and detected by a microcontroller interrupt. The microcontroller can then use an in-
ternal counter to re-time the SYNC signal output to the digital filter SYNC input as required.
A microcontroller software connection is made when the SYNC signal output is created by the microcon-
troller on command from the system telemetry. The microcontroller can use an internal counter to re-time
the SYNC signal output to the digital filter SYNC input as required.
DS639RD2
Specification
RS-485 Transceiver - Linear Tech
Surface Mount Package Type
Supply Voltage, Quiescent Current
Maximum Data Rate
Transmitter Delay, Receiver Delay
Transmitter Current, Full Termination (60 Ω)
Transmitter Current, Half Termination (120 Ω)
Specification
Synchronous Inputs, 2 wires each
Specification
Distributed SYNC Signal Synchronization
Distributed Clock Synchronization
Analog Sampling Synchronization Accuracy
CLK, SYNC
2
C interface and the clock and synchronization inputs.
Value
LTC1480IS8
SOIC-8, 5mm x 6mm
3.3V, 600 µA
2.5 Mbps
25 - 80 ns, 30 - 200 ns
25 mA
13 mA
Value
CLK±, SYNC±
Value
± 240 ns
± 240 ns
± 480 ns
CRD5378
25

Related parts for CRD-5378