PD1201S Clare, PD1201S Datasheet
PD1201S
Specifications of PD1201S
Related parts for PD1201S
PD1201S Summary of contents
Page 1
... Approvals • UL Recognized Component: UL 508 File E69938 • CSA Certified Component: Certificate LR43639-8 Ordering Information Part # PD1201 Pin Configuration - LED AC Load www.clare.com PD1201 AC Power Switch and max surge P Description 4-Pin (16-Pin Body) DIP Package (25/Tube LED Load ...
Page 2
... Conditions Symbol I =5mA =120-240VAC t<16ms I PEAK V =400V LEAK I =1. rms - dV/ =5mA F t off st 1 half-cycle - Subsequent half-cycle - - - I =5mA = www.clare.com PD1201 Min Typ Max Units 20 - 120 V 0.005 - 1.2 V 1000 1200 - V/µ 0.5 Cycles - - 0 500 0. 0.9 1.2 1.4 0 rms rms ...
Page 3
... NOTE: Values apply to T =50ºC before Surge Pulse Duration (ms) PD1201 dV/dt Method 300V 63% dV 0.63 x 300V 189 = = accordance with EIA/NARM Standards 10% RS-443 for Solid State Relays 85 RC www.clare.com PD1201 PD1201 Typical Forward Voltage vs. Temperature 1.3 1.2 1.1 1.0 0.9 100 Ambient Temperature (º ...
Page 4
... Clare recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since Clare employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. ...
Page 5
... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage ...