E3X-SD/-NA
Nomenclature
Amplifier Units
E3X-SD
Operating Procedure
E3X-SD
The sensitivity can be set with the UP and DOWN Keys similar
to using an adjuster knob. The sensitivity can also be easily
set by using the following two teaching functions.
Two points (one with the workpiece and the other without) are
detected, and the operating level is set to the midpoint.
Light level is also automatically set to the optimal value.
Changes within a time are detected, and the operating level is
set to the midpoint between the maximum and the minimum
values of the changes. This setting is optimal for when the
workpieces cannot be stopped. Execute automatic teaching
again if the incident light level is not automatically set to the
optimal value.
Teaching status
indication(orange)
Press the TEACH button with the workpiece.
Press the TEACH button without the
workpiece.
Press the TEACH button for 3 s min. Let the
workpiece pass while the button is pressed.
Lock Lever
1
2-1. Teaching with/without a Workpiece
2-2. Automatic Teaching
Digital incident light level display or
digital threshold value display (red)
Display of contents of functions
during operation
Operation Indicator
(Orange)
Sensitivity Setting
Operation description
Operation description
Light-ON and
Dark-ON Indicator
Digital threshold value adjustment
(UP/DOWN)
Teaching Button
The sensitivity and threshold
value can be set automatically.
Button/Key
Button/Key
Operation Selector
Use to switch between
Light-ON and Dark-ON
TEACH
TEACH
TEACH
E3X-NA
A bar display (with four green and one red) showing excess
gain is provided in addition to the orange operation indicator.
Use these when adjusting the light axis and setting the
sensitivity at setup.
E3X-NA
Lock lever
1
Display/indicator status (for L/ON)
Displays
Operation indicator
Operation Indicator
Incident level indicators
Excess gain level display
Sensitivity indicator
8-turn sensitivity adjuster
110% to 120%
90% to 110%
Excess gain
80% to 90%
Timer switch
ON: Timer function is ON.
OFF: Timer function is OFF.
120% min.
80% max.
Approx.
Approx.
Approx.
Approx.
Approx.
level
Operation Selector
Use to switch between
Light-ON and Dark-ON
interrupted light
interrupted light
incident light or
Stable incident
Description
Unstable
Unstable
Stable
light