E3X-CN11 5M Omron, E3X-CN11 5M Datasheet - Page 12

no-image

E3X-CN11 5M

Manufacturer Part Number
E3X-CN11 5M
Description
Photoelectric Sensors - Industrial 5m E3X-Da Cable
Manufacturer
Omron
Datasheet

Specifications of E3X-CN11 5M

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
12
E3X-SD/-NA
Fiber Connection and Disconnection
The E3X Amplifier Unit has a lock lever. Connect or
disconnect the fibers to or from the E3X Amplifier Unit using
the following procedures:
1. Connection
Open the Protective Cover, insert the fibers according to the
fiber insertion marks on the side of the Amplifier Unit, and
lower the lock lever.
2. Disconnection
Remove the Protective Cover and raise the lock lever to pull
out the fiber.
Note:To maintain the fiber properties, confirm that the lock is
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock lever within an ambient
temperature range between −10°C and 40°C.
● Operating Environment
Ambient Conditions
If dust or dirt adhere to the hole for optical communications, it
may prevent normal communications. Be sure to remove any
dust or dirt before using the Units.
● Other
Protective Cover
Be sure to mount the Protective Cover before use.
Amplifier Units with Connectors
● Mounting
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
2. Join Amplifier Units together as required after all the Master
3. Attach the stickers (provided as accessories) to the sides of
until it clicks into place.
and Slave Connectors have been inserted.
Master and Slave Connectors that are not connected to
other Connectors.
Lock lever
Fiber
released before removing the fiber.
Fiber insertion mark
Locked
Unlocked
10.7 mm
Protective Cover
Insert
Insertion position
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to
2. After the Amplifier Unit has been separated, press down on
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move
during operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the
master Amplifier Unit using a nipper or similar tool.
The clip can also be removed using the following mechanism,
which is incorporated in the construction of the section
underneath the clip.
1. Insert the clip to be removed into the slit underneath the clip
2. Remove the clip by rotating the Amplifier Unit.
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
be removed away from the rest of the group.
the lever on the Connector and remove it. (Do not attempt
to remove Connectors without separating them from other
Amplifier Units first.)
on another Amplifier Unit.
Rotate
Sticker
Clip
Press down
Sticker
Remove
Lever

Related parts for E3X-CN11 5M