CDB5461AU

Manufacturer Part Number
CDB5461AU
Description
Eval Bd Sngl Phase Power/Energy
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5461AU

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS5461A
Primary Attributes
1-Phase, Energy-to-Frequency Output
Secondary Attributes
GUI, USB, SPI, Microwire Interfaces
Processor To Be Evaluated
CS5461A, C8051F320
Interface Type
USB
Operating Supply Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Contains lead / RoHS non-compliant
Other names
598-1552
2.8.7.6
The value in Cycle Count field will be written to the CS5461A’s Cycle Count register. Cycle Count determines the
length of one computation cycle. Cycle Count should be selected appropriately according to the Data to Collect se-
lection. For example, if the Data to Collect is instantaneous Current, Voltage, or Power, it is better to set Cycle Count
to 1. If the data to collect is RMS Current, RMS Voltage, or Average Power, Cycle Count should be set to a value
that makes one computation cycle to be a even multiple of the line frequency.
2.8.7.7
When this button is pressed, the current settings will be saved, and the user will return to the Data Collection window.
2.8.8
To collect a sample data set:
2.8.9
The CDB5461AU software allows the user to save data to a file, and retrieve it later when needed. To load a previ-
ously saved file:
2.8.10 Analyzing Data
The evaluation software provides three types of analysis tests: Time Domain, Frequency Domain, and Histogram.
The Time Domain analysis process acquires conversions to produce a plot of magnitude versus conversion sample
number. The Frequency Domain analysis process acquires conversions to produce a plot of magnitude versus fre-
quency using the Fast-Fourier Transform (results up to Fs/2 are calculated and plotted). Also statistical noise calcu-
lations are calculated and displayed. The Histogram analysis test process acquires conversions to produce a
histogram plot. Statistical noise calculations are also calculated and displayed.
DS661DB1
Collecting Data Sets
Retrieving Saved Data from a File
Cycle Count
Accept Button
1. In the Data Collection Window, press the Config button to bring up the Configuration Window and
2. Select the appropriate settings from the available options (see the section on the Configuration Win-
3. The Data Collection Window should still be visible. Press the Collect button to begin collecting data.
4. Once the data has been collected, it can be analyzed, printed, or saved to disk.
1. Pull down the Setup option and select Disk. A file menu will appear.
2. Find the data file in the list and select it. Press the select button to return.
3. Go to the Data Collection Window, and press the Collect button.
4. The data from the file should appear on the screen. To select a different file, repeat the procedure.
view the current settings.
dow) and press the Accept button.
CDB5461AU
21