3.2.6 Latch_INT:
If this bit (address 15h, bit 4) is at 1, interrupts are latched. The INT pad stays high until
microprocessor detects it and writes reset_INT control bit to 1 (section 3.3.1). When this bit is at
0, interrupts are set and reset directly by BMA150 according to programmable criteria (sections
3.2.7 and 3.2.8).
3.2.7 LG_thres, LG_hyst, LG_dur, counter_LG
LG_thres (address 0C, bits 7-0 / low-g threshold) and LG_hyst (address 11h, bits 2-0 / low-g
threshold hysteresis) are used to detect a free fall. The threshold and duration codes define one
criterion for interrupt generation when absolute value of acceleration is low for long enough
duration.
Data format is unsigned integer.
LG_thres criterion_x is true if
LG_thres interrupt is set if
LG_thres criterion_x is false if
LG_thres interrupt is reset if
LG_thres and LG_hyst codes must be chosen to have (LG_thres + 32*LG_hyst) < 511.
When LG_thres criterion becomes active, an interrupt counter is incremented by 1 LSB/ms.
When the low-g interrupt counter value equals (LG_dur+1), an interrupt is generated.
Depending on counter_LG (address 0Bh, bit 3 and 2) register, the counter could also be reset
or count down when LG_thres criterion is false.
Table 6: Description of debouncing counter counter_LG
If latch_INT=0, the interrupt is not a latched interrupt and then it is reset as soon as LG_thres
criteria becomes false. When interrupt occurs, the interrupt counter is reset.
The LG_thres criteria is set with an AND condition on all three axes to be used for free fall
detection.
Rev. 1.5
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
counter_LG<1:0>
00
01
10
11
low acceleration interrupt counter status when
Triaxial, digital acceleration sensor
LG_thres criteria is false
Count down by 1 LSB/ms
Count down by 2 LSB/ms
Count down by 3 LSB/ms
|acc_x |
(LG_thres criterion_x AND LG_thres criterion_y AND
LG_thres criterion_z) AND interrupt counter = (LG_dur+1)
|acc_x | > (LG_thres + 32*LG_hyst) / 255 * range
NOT(LG_thres criterion_x AND LG_thres criterion_y AND
LG_thres criterion_z)
reset
Data sheet
BMA150
Page 15
LG_thres / 255 * range