6057 3M, 6057 Datasheet

no-image

6057

Manufacturer Part Number
6057
Description
FILTER, ABEI BOX OF 8
Manufacturer
3M
Datasheet

Specifications of 6057

Conforms To
EN141
Occupational Exposure Level
10
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
NA
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
6057
Quantity:
5 510
Part Number:
6057
Manufacturer:
PANASONIC
Quantity:
5 510
Part Number:
6057
Manufacturer:
PANASONIC/松下
Quantity:
20 000
Part Number:
60573-1
Manufacturer:
TE
Quantity:
50 835
Part Number:
60577-1
Manufacturer:
TE
Quantity:
80 000
Part Number:
60577-1
Manufacturer:
JST
Quantity:
35 000
6000 Half/English
Scale=1 inch
3/19/98 3M Packaging Preview, St. Paul
4/02/98 3M Electronic Routing, St. Paul
5/08/98 Westgate/Lee, 3M Canada
5/08/98 N. Lamarche, 3M Montreal
5/06/98 F. Cruz, 3M Mexico
5/07/98 M.C. León, 3M Colombia
5/07/98 E. Guterman, 3M Brazil
4/02/98 3M Final Approval, St. Paul
Supersedes:
ARTWORK INFORMATION
Artwork #:
Structure:
Author:
3M APPROVALS:
Date:
34#:
6/1/98 2:50 PM
OH-8500-5087
34-7042-2323-8
OH-8500-3828
KA
5/28/98
Manual 4" x 5.25"
(3291)
All copy and graphics
print black.
Output at 100%
Page 1

6057 Summary of contents

Page 1

... Manual 4" x 5.25" All copy and graphics print black. Scale=1 inch Output at 100% 3M APPROVALS: 3/19/98 3M Packaging Preview, St. Paul 4/02/98 3M Electronic Routing, St. Paul 5/08/98 Westgate/Lee, 3M Canada 5/08/98 N. Lamarche, 3M Montreal 5/06/98 F. Cruz, 3M Mexico 5/07/98 M.C. León, 3M Colombia 5/07/98 E. Guterman, 3M Brazil 4/02/98 3M Final Approval, St. Paul Page 1 ...

Page 2

... C.P. 5757 Impreso en papel reciclado en un 50%, London (Ontario) N6A 4T1 incluyendo 10% de papel ya usado por los Imported by/Importado por: consumidores. 3M México S.A. de C.V. Impreso en los Estados Unidos de Calz. San Juan de Aragón 516 América. México, D.F. 07070 RFC TMM-720509 PYA ...

Page 3

... PM 3 6000 Series Half Facepiece Respirator User Instructions Respirateurs à demi-masque de série 6000 Directives d’utilisation Respirador Media Máscara Serie 6000 3M Instrucciones de uso Respirador semifacial 3M série 6000 Instruções de uso Important: Read and understand all safety information before using. ...

Page 4

Half/English 6/1/98 2:50 PM Page 4 ...

Page 5

... For assistance with operation and application of products from 3M Occupational Health and Environmental Safety Division (OH&ESD), please call your 3M representative at 1-800-896-4223 or call 3M Technical Service at 1-800-243-4630. In Canada, call 3M OH&ESD at 1-800-265-1840, extension 6137 or 1-519-452-6137. SAVE THIS USER INSTRUCTIONS AND KEEP IT WITH THE RESPIRATOR. ...

Page 6

... Half/English 6/1/98 2:50 PM GENERAL SAFETY INFORMATION Intended Use: The 3M™ 6000 Series Half Facepiece Respirators are designed to help provide respiratory protection against certain airborne contaminants when used in accordance with all use and limitation instructions and applicable safety and health regulations. ...

Page 7

... User Instructions. Keep insert for reference. Use For: Respiratory protection from certain airborne contaminants according to NIOSH approvals, OSHA limitations, in Canada CSA standard Z94.4-93 requirements, other applicable regulations and 3M instructions. Do Not Use For: Concentrations of contaminants which are immediately dangerous to life and health, are unknown or when concentrations exceed 10 ...

Page 8

Half/English 6/1/98 2:50 PM Use Instructions: Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can reduce respirator effectiveness and may result in sickness ...

Page 9

Half/English 6/1/98 2:50 PM Time Use Limitations: If respirator becomes damaged, leave contaminated area and dispose of respirator. Replace filters in accordance with the filter Time Use Limitation. User Instructions.) (See filter Replace cartridges in accordance with an established ...

Page 10

... Refer to instruction manual before donning. Special Use Instructions: 3M™ Mercury Vapor Cartridges (6009 and 60929) are equipped with passive 3M™ End of Service Life Indicators (ESLI). The color change indicator must be readily visible when wearing the respirator without manipulation. If you cannot readily see the ESLI, do not use ...

Page 11

... Half/English 6/1/98 2:50 PM LIST OF PRODUCTS 3M™ 6000 Series Reusable Dual Cartridge Respirator 3M™ Facepieces Half Facepiece assemblies Half Facepiece assemblies (minus cartridges, filters, (with probe for quantitative fit retainers, and prefilters) testing, includes 2091 P100 filters) 6100 small 6100Q small ...

Page 12

... Half/English 6/1/98 2:50 PM 3M™ Cartridges Number Product Name NIOSH Approval (for respiratory protection against the following contaminants up to ten times the permissible exposure limit) 6001 Organic Vapor Certain organic vapors 6002 Acid Gas Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) ...

Page 13

... Special Use Instructions 3M Mercury Vapor Cartridges (6009 and 60929) are equipped with passive End of Service Life Indicators (ESLI). The color change indicator must be readily visible when wearing the respirator without manipulation. If you cannot readily see the ESLI, do not use respirator and do not enter contaminated area ...

Page 14

... P100 Particulate filter with nuisance level organic vapor relief* 5N11 N95 Particulate filter 5P71 P95 Particulate filter 7093 P100 Particulate filter *3M recommended for relief against nuisance levels of acid gas or organic vapors. Nuisance level refers to concentrations not exceeding OSHA PEL or applicable exposure limits, whichever is lower. 10 Page 10 ...

Page 15

... Align cartridge notch with facepiece mark, as shown, and push together. (Figure 1) 2. Turn cartridge clockwise to stop (1/4 turn). (Figure 2) Fig. 1 Prefilter Assembly Instructions (for 3M™ 5N11 and 5P71 Filters) 1. Place filter into 3M™ 501 Retainer so printed side of filter faces the cartridge. ...

Page 16

... Fig Engage back snap by squeezing back side of cartridge and adapter together using the same hand positions. An audible click should be heard as each snap is engaged. The 3M 502 adapter should not be removed or reused once engaged not designed for reuse and leakage may occur. (Figure 2) ...

Page 17

... The 3M 502 adapter once installed on a 3M™ 6000 Series Cartridge is not to be removed and reused as leakage may occur. Assembly of 3M™ Dual Airline 1. Hold the half facepiece in front of you so that the 3M logo on half facepiece is facing you. Align the two branches of the breathing tube over the two bayonet mounts on half facepiece. ...

Page 18

... Assembly of 3M™ Combination Dual Airline Respirator with Cartridges and Filters The 3M™ SA-1600 (front-mounted) and SA-2600 (back-mounted) versions of the 3M dual airline breathing tubes allow use of selected, NIOSH-approved 3M™ 6000 Series Cartridges and 2000 Series Filters. For listing of approved cartridges and filters, reference NIOSH approval label included with 3M dual airline breathing tubes ...

Page 19

... If a proper fit cannot be obtained, see your supervisor. Do not enter contaminated area. 6. Attach an airline to the 3M™ SA-1009 Air Regulator or SA-1029 Low Pressure Connector and adjust air pressure to the specified setting for length of air supply hose employed. ...

Page 20

Half/English 6/1/98 2:50 PM FITTING INSTRUCTIONS Must be followed each time respirator is worn Donning Respirator 1. Place respirator over your mouth and nose, then pull head harness over crown of your head. (Figure 1) 2. Take bottom straps ...

Page 21

... Fit testing is a U.S. Occupational Safety and Health Administration (OSHA) and Canadian CSA requirement. Quantitative Fit Testing (QNFT) can be conducted using a 3M™ 601 Fit Test Adapter and 42 CFR 84 P100 filters such as the 3M™ 2091 or 7093 Particulate Filters. Qualitative Fit Testing (QLFT) with the 3M™ FT-10 or FT-30 Qualitative Fit Test Apparatus can be conducted using any of the NIOSH approved 42 CFR 84 particulate filters ...

Page 22

Half/English 6/1/98 2:50 PM SEAL CHECK FOR 6000 SERIES CARTRIDGES Always Check the Seal of the Respirator on Your Face Before Entering a Contaminated Area. Positive Pressure Seal Check Place the palm of your hand over the exhalation valve ...

Page 23

... Repeat above steps until a tight face seal is obtained. If you cannot achieve a proper fit, DO NOT enter contaminated area. See your supervisor. Note: Use of 3M 501 filter retainer may aid respirator wearer in conducting a negative pressure seal check. 19 Page 19 ...

Page 24

Half/English 6/1/98 2:50 PM SEAL CHECK FOR 2000 SERIES FILTERS Always Check the Seal of the Respirator on Your Face Before Entering a Contaminated Area. Positive Pressure Seal Check Place the palm of your hand over the exhalation valve ...

Page 25

Half/English 6/1/98 2:50 PM Negative Pressure Seal Check Place your thumbs onto the center portion of the filters, restricting airflow into the breathing tube of filters, and inhale gently. If you feel facepiece collapse slightly and pull closer to ...

Page 26

... Half/English 6/1/98 2:50 PM INSPECTION PROCEDURE The 3M™ 6000 Series Respirator must be inspected before each use to ensure that good operating condition. The facepiece should be disposed of upon observation of damaged or defective parts. The following inspection procedure is suggested. 1. Check facepiece for cracks, tears and dirt. Be certain facepiece, especially face seal area, is not distorted ...

Page 27

... CLEANING AND STORAGE INSTRUCTIONS Cleaning is recommended after each use. 1. Remove cartridges and/or filters. 2. Clean facepiece (excluding filters and cartridges), with 3M™ 504 Respirator Wipes or by immersing in warm cleaning solution, water temperature not to exceed 120˚F, and scrub with soft brush until clean. Add neutral detergent if necessary ...

Page 28

... The foregoing may not be changed except by written agreement signed by an authorized officer of 3M. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE ...

Page 29

... Tel: 54-1-469-8200 Costa Rica Australia 3M Costa Rica, S.A. 3M Australia Pty. Ltd. San Jose Pymble, N.S.W. Tel: 506-260-3333 Tel: 61-2-9498-9333 Czech Republic Austria 3M Cesko, Spol. SRO 3M Oesterreich Ges M.h.H. Czech Republic Vienna Telephone: 422-255-145 Tel: 43-1-866860 Denmark Belgium 3M A/S 3M Belgium N.V./S.A. Glostrup ...

Page 30

... Tel: 91-80-5588881 Tel: 82-2-3771-4114 Indonesia Malaysia P.T. 3M Indonesia 3M Malaysia Sdn. Berhad Jakarta Kuala Lumpur Tel: 62-21-5212166 Tel: 603-775-7555 Ireland Mexico 3M Ireland – 3M House 3M México, S.A. de C.V. Co. Dublin México Tel: 353-1-2803555 Tel: 52-5-626-0400 26 Page 26 Morocco 3M Maroc Casablanca, Maroc Tel: 212-2-984965 Netherlands 3M Nederland B ...

Page 31

... Trinidad 3M South Africa (Pty.) Ltd. 3M Interamerica, Inc. Johannesburg Port of Spain Tel: 27-11-922-9111 Tel: 809/623-8917 Spain Turkey 3M Espana, S.A. 3M Sanayii ve Ticaret A.S. Madrid Istanbul Tel: 34-1-321-60-00 Tel: 90-212-282-23 82 Sri Lanka United Kingdom 3M Lanka (Private) Limited 3M United Kingdom PLC Pelawatte, Battaramulla Bracknell, Berkshire ...