N5181A-506 AGILENT TECHNOLOGIES, N5181A-506 Datasheet

SIGNAL GENERATOR, FREQUENCY/PULSE, 6GHZ

N5181A-506

Manufacturer Part Number
N5181A-506
Description
SIGNAL GENERATOR, FREQUENCY/PULSE, 6GHZ
Manufacturer
AGILENT TECHNOLOGIES
Series
N5181Nr
Datasheet

Specifications of N5181A-506

Signal Generator Type
Sweep Function
Bandwidth
6GHz
External Height
103mm
External Width
426mm
External Depth
432mm
Kit Contents
2RU
Analyzer Functions
Frequency
Lead Free Status / RoHS Status
na
Agilent N5181A
MXG
and N5161A MXG ATE
s
Analog
Signal Generator
Optimized for
Data Sheet
performance and speed
• Fast switching speeds
• Simplified self-maintenance
• High output power

N5181A-506 Summary of contents

Page 1

... Agilent N5181A and N5161A MXG ATE Analog Signal Generator MXG s Optimized for Data Sheet performance and speed • Fast switching speeds • Simplified self-maintenance • High output power ...

Page 2

Table of Contents 2 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 3

... Data represented in this document are specifications unless otherwise noted. The specifications in this data sheet also apply to the N5181AEP MXG analog RF signal generator express configuration. For more information about the express MXG, see the technical overview 5990-7629EN. Typical (typ): Represents characteristic performance, which 80% of the instruments manufactured will meet ...

Page 4

Frequency 4 Range Option 501 100 kHz to 1 GHz Option 503 100 kHz to 3 GHz Option 506 100 kHz to 6 GHz Minimum frequency 100 kHz Resolution 0.01 Hz Phase offset Adjustable in nominal 0.01° increments 2 Frequency ...

Page 5

Accuracy ± aging rate ± temperature effects ± line voltage effects I nternal time base reference oscillator aging rate ≤ ± 5 ppm/10 yrs, < ± 1 ppm/yr (nom) Temperature effects ± 1 ppm ( °C) (nom) Line ...

Page 6

Amplitude 6 1 Output power Minimum output power –110 dBm 2 with Option 1EQ –127 dBm Maximum output power Range Standard 100 kHz to 250 kHz +13 dBm > 250 kHz to 50 MHz +13 dBm > 50 MHz to ...

Page 7

Switching speed Type Standard SCPI mode ≤ (typ) List/Step sweep mode ≤ (typ) 3 Absolute level accuracy [ALC on] 4 +23 to –60 dBm < –60 to –110 dBm 5 100 kHz to 250 ...

Page 8

Level accuracy at –110 dBm 1 0.8 0.6 0.4 0.2 0 –0.2 –0.4 –0.6 –0.8 –1 0 1000 2000 3000 Frequency (MHz) 8 Absolute level accuracy [ALC off, relative to ALC on] 1 0.8 0.6 0.4 0.2 0 –0.2 –0.4 ...

Page 9

Amplitude repeatablity +5 dBm ALC on 0.5 0.4 0.3 0.2 0.1 0 –0.1 –0.2 –0.3 –0.4 –0 Elapsed time (minutes) Repeatability measures the ability of the instrument to return to a given power setting after a random ...

Page 10

ALC linearity 850 MHz, CW, relative to 0 dBm 0.3 0.2 0.1 0 –0.1 –0.2 –0.3 –20 –15 –10 –5 Amplitude (dB) ALC linearity 2200 MHz, CW, relative to 0 dBm 0.3 0.2 0.1 0 –0.1 –0.2 –0.3 –20 –15 ...

Page 11

Spectral Purity User flatness correction Number of points 3201 Number of tables Dependent on available free memory in instrument; 10000 maximum Entry modes USB/LAN direct power meter control, LAN to GPIB and USB to GPIB, remote bus and manual USB/GPIB ...

Page 12

AM noise at 1 GHz -60.00 -70.00 -80.00 -90.00 -100.0 -110.0 -120.0 -130.0 -140.0 -150.0 -160.0 -170.0 -180.0 10 100 1k 10k Residual FM [CW mode, 300 kHz BW, CCITT, rµs] 1 Harmonics [CW mode, output ...

Page 13

Analog Modulation 1 Frequency modulation (Option UNT) Max deviation MHz (nom) Resolution 0.1% of deviation or 1 Hz, which ever is greater (nom) Deviation accuracy [1 kHz rate, deviation kHz] < ±2% + ...

Page 14

Internal analog modulation source (Single sine wave generator for use with AM, FM, phase modulation. Requires Option UNT) Waveform Sine Rate range 0 MHz (tuneable to 3 MHz) Resolution 0.1 Hz Frequency accuracy Same as RF ...

Page 15

Td Video delay (variable) Sync Tw Video pulse width (variable) output Tp Pulse period (variable delay Video Trf RF pulse width output Tf RF pulse fall time Tr RF pulse rise time Vor Pulse overshoot RF pulse Vf ...

Page 16

... AS/NZS CISPR 11:2002 • ICES/NMB-001 Memory is shared by instrument states, sweep list files, and other files. There are flash memory available in the N5181A MXG. Depending on how the memory is utilized, a maximum of 1000 instrument states can be saved. Memory sanitizing, memory sanitizing on power on, and display blanking Internal diagnostic routines test most modules in a preset condition ...

Page 17

... In support of this commitment, Agilent has verified that the stability of this product's architecture justifies a longer calibration interval of 3 years. ISO compliant The Agilent N5181A MXG is manufactured in an ISO-9001 registered facility in concurrence with Agilent Technologies’ commitment to quality. 1 Front panel connectors ...

Page 18

Ordering Information 18 LAN (100 BaseT) The LAN connector provides the same SCPI remote programming functionality as the GPIB connector. The LAN connector is also used to access the internal web server and FTP server. The LAN supports DHCP, sockets ...

Page 19

Archive Section Frequency Minimum frequency 100 kHz 2 Output power Range (for serial number 100 kHz to 250 kHz prefix 4742xxxx) > 250 kHz to 2.5 GHz –110 to +13 dBm > 2.5 to 3.0 GHz > 3.0 to 4.5 ...

Page 20

Maximum available output power Maximum available output power 1000 1000 2000 2000 Frequency (MHz) Frequency (MHz) SWR ≤ 2.1 ...

Page 21

Spectral Purity (for serial numbers lower than 4818xxxx) 1 Harmonics [CW mode, output level < 4 dBm] 250 kHz to 3 GHz < –30 dBc > 3 GHz to 6 GHz < –44 dBc (typ) 1 Nonharmonics [CW mode], > ...

Page 22

... Agilent MXG Signal Generator, Brochure, literature number 5989-5074EN • Agilent MXG Signal Generator, Configuration Guide, literature number 5989-5485EN • Agilent N5181A analog signal generator, Data Sheet, literature number 5989-5311EN • E4438C ESG Vector Signal Generator, Brochure, literature number 5988-3935EN. • E4438C ESG Vector Signal Generator, Configuration Guide, literature number 5988-4085EN. ...