Specifications of DPO5054

Scope Type
Digital Bench
Scope Channels
4 Analog
Bandwidth
500MHz
Meter Display Type
XGA LCD
Sampling Rate
5GSPS
Input Impedance
1Mohm
Rise Time
700ps
Input Voltage
300Vrms
Configuration
Benchtop
Number Of Channels
4
Sample Rate
5 GS/s
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Data Sheet
Options
Record Length Options
Software Options
18
Option
Opt. 2RL
Opt. 5RL
Opt. 10RL
Option
Opt. DDRA*
Opt. DJA
Opt. ET3*
Opt. LT
Opt. MTM
Opt. PWR
Opt. SR-COMP
Opt. SR-EMBD
Opt. SR-USB
Opt. USB*
Opt. VNM
www.tektronix.com
2
3
1
Description
DDR Memory Bus Analysis
Jitter and Eye Analysis Tools – Advanced (DPOJET)
Ethernet Compliance Testing
Waveform Limit Testing
Mask Testing
Power Measurement and Analysis
Computer Serial Triggering and Analysis
(RS-232/422/485/UART)
Enables triggering on packet-level information on
RS-232/422/485/UART buses as well as analytical tools
such as digital views of the signal, bus views, and packet
decoding.
Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on
MSO models)
Recommended Probing – RS-232/UART: Single ended;
RS-422/485: Differential
Embedded Serial Triggering and Analysis (I
Enables triggering on packet-level information on I
and SPI buses as well as analytical tools such as digital
views of the signal, bus views, and packet decoding.
Signal Inputs – I
MSO models); SPI: Any Ch1 - Ch4 (and any D0 - D15
on MSO models)
Recommended Probing – I
USB Serial Triggering and Analysis (LS, FS, HS)
Enables triggering on packet-level content for low-speed,
full-speed, and high-speed USB serial buses. Also
enables analytical tools such as digital views of the
signal, bus views, and packet decoding for low-speed,
full-speed, and high-speed USB serial buses.
Signal Inputs – Low-speed and Full-speed: Any Ch1
- Ch4 (and any D0 - D15 on MSO models) for single
ended, Any Ch1 - Ch4 for differential; High-speed: Any
Ch1 - Ch4
Recommended Probing – Low-speed and Full-speed:
Single ended or differential; High-speed: Differential
USB high-speed supported only on MSO5204,
DPO5204, MSO5104, and DPO5104 models.
USB 2.0 Compliance Testing
CAN/LIN Protocol Analysis Software
– ITU-T (64 Kb/s to 155 Mb/s)
– ANSI T1.102 (1.544 Mb/s to 155 Mb/s)
– Ethernet IEEE 802.3, ANSI X3.263 (125 Mb/s to
1.25 Gb/s)
– Sonet/SDH (51.84 Mb/s to 622 Mb/s)
– Fibre Channel (133 Mb/s to 2.125 Gb/s)
– Fibre Channel Electrical (133 Mb/s to 1.06 Gb/s)
– USB (12 Mb/s to 480 Mb/s)
– IEEE 1394b (491.5 Mb/s to 1.966 Gb/s)
– Rapid I/O Serial (up to 1.25 Gb/s)
– Rapid I/O LP-LVDS (500 Mb/s to 1 Gb/s)
– OIF Standards (1.244 Gb/s)
– CPRI, V4.0 (1.228 Gb/s)
– Video (143.18 Mb/s to 360 Mb/s)
MSO5034
MSO5054
DPO5034
DPO5054
125M/Ch
25M/Ch
50M/Ch
2
C: Any Ch1 - Ch4 (and any D0 - D15 on
2
C, SPI: Single ended
250M max, 125M/Ch
125M max, 50M/Ch
50M max, 25M/Ch
MSO5104
DPO5104
MSO5204
DPO5204
2
C, SPI)
2
C
*
*
*
Power Plug Options
User Manual Options
Service Options*
*
Option
Bundle Options
Opt. PS1
Floating licenses offer an alternative method to manage your Tektronix asset.
Floating licenses allow license-key enabled options to be easily moved among all
your MSO/DPO5000, DPO7000, and DPO/DSA/MSO70000 Series of Tektronix
oscilloscopes. Floating licenses are available for many license-key enabled
options. To order a floating version of an option license add “DPOFL-“ prefix to
the option name. (e.g. DPOFL-ET3)
Check www.tek.com/products/oscilloscopes/floatinglicenses for additional
information about floating license options.
Option
Opt. A0
Opt. A1
Opt. A2
Opt. A3
Opt. A5
Opt. A6
Opt. A10
Opt. A11
Opt. A12
Opt. A99
Option
Opt. L0
Opt. L1
Opt. L3
Opt. L5
Opt. L7
Opt. L8
Opt. L9
Opt. L10
Option
Opt. CA1
Opt. C3
Opt. C5
Opt. D1
Opt. D3
Opt. D5
Opt. G3
Opt. G5
Opt. R3
Opt. R5
1
2
3
4
Requires Opt. DJA. Available on 1 GHz and 2 GHz models only.
Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture.
Requires TDSUSBF (USB Test Fixture). 2 GHz bandwidth required for high-speed USB.
Probes and accessories are not included in the oscilloscope warranty. Refer to the data sheet for each
probe for its unique warranty and calibration terms.
4
Description
Power Solution Bundle: DPOPWR, P5205, TCP0030,
TPA-BNC, 067-1686-xx (Deskew Fixture)
Description
North America
Universal European Union
UK
Australia
Switzerland
Japan
China
India
Brazil
No power cord
Description
English manual
French manual
German manual
Japanese manual
Simplified Chinese manual
Traditional Chinese manual
Korean manual
Russian manual
Description
Provides a single calibration event, or coverage for the
designated calibration interval, whichever comes first
Calibration Service 3 Years
Calibration Service 5 Years
Calibration Data Report
Calibration Data Report 3 Years (with Opt. C3)
Calibration Data Report 5 Years (with Opt. C5)
Complete Care 3 Years (includes loaner, scheduled
calibration, and more)
Complete Care 5 Years (includes loaner, scheduled
calibration, and more)
Repair Service 3 Years (including warranty)
Repair Service 5 Years (including warranty)