DPO5054 Tektronix, DPO5054 Datasheet

no-image

DPO5054

Manufacturer Part Number
DPO5054
Description
OSCILLOSCOPE, 4 CHANNEL, 500MHZ, 5GSPS
Manufacturer
Tektronix
Type
Mixed Signalr
Datasheet

Specifications of DPO5054

Scope Type
Digital Bench
Scope Channels
4 Analog
Bandwidth
500MHz
Meter Display Type
XGA LCD
Sampling Rate
5GSPS
Input Impedance
1Mohm
Rise Time
700ps
Input Voltage
300Vrms
Configuration
Benchtop
Number Of Channels
4
Sample Rate
5 GS/s
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Mixed Signal Oscilloscopes
MSO5000, DPO5000 Series Data Sheet
Features & Benefits
Key Performance Specifications
Ease-of-Use Features
2 GHz, 1 GHz, 500 MHz, and 350 MHz Bandwidth Models
Up to 10 GS/s Real-time Sample Rate on One or Two Channels and
up to 5 GS/s on All Four Channels
Up to 250 Megapoint Record Length with MultiView Zoom™
>250,000 wfms/s Maximum Waveform Capture Rate with FastAcq™
FastFrame Segmented Memory Acquisition Mode with >310,000 Frames
per Second Capture Rate
Standard Passive Voltage Probes with Less than 4 pF Capacitive
Loading and 500 MHz or 1 GHz Analog Bandwidth
16 Digital Channels (MSO Series)
User-selectable Bandwidth Limit Filters for Better Low-frequency
Measurement Accuracy
Suite of Advanced Triggers
Wave Inspector
Search of Waveform Data
MyScope
Exceptional Efficiency
®
Custom Control Windows and Right Mouse Click Menus for
®
Controls provide Easy Navigation and Automated
Connectivity
Mixed Signal Design and Analysis (MSO Series)
Optional Serial Triggering and Analysis
Optional Technology Specific Analysis
53 Automated Measurements, Waveform Histograms, and FFT Analysis
for Simplified Waveform Analysis
TekVPI
Probes for Automatic Scaling and Units
10.4 in. (264 mm) Bright XGA Display with Touch Screen
Small Footprint and Lightweight – Only 8.12 in. (206 mm) Deep and Less
than 15 lb. (6.7 kg)
Two USB Host Ports on the Front Panel and Four on the Rear Panel
for Quick and Easy Data Storage, Printing, and Connecting USB
Peripherals
USB Device Port on the Rear Panel for Easy Connection to a PC or
GPIB Control with an Adapter
Integrated 10/100/1000BASE-T Ethernet Port for Network Connection
and Video Out Port to Export the Oscilloscope Display to a Monitor or
Projector
Microsoft
and Integration into Your Environment
LXI Class C Compliant
Automated Triggering and Decode on Parallel Buses
Per-channel Threshold Settings
MagniVu™ High-speed Acquisition provides 60.6 ps Fine Timing
Resolution on Digital Channels
Automated Serial Triggering and Decode Options for I
RS-232/422/485/UART, and USB
Automated Serial Decode and Vehicle Network Monitoring of CAN and
LIN
Software Solutions provide Built-in Domain Expertise for Ethernet and
USB 2.0 Compliance Testing, Jitter, Timing, Eye Diagrams, Power, and
DDR Memory Bus Analysis
Limit and Mask Testing provide Quick Insight into Signal Characteristics
®
Probe Interface supports Active, Differential, and Current
®
Windows 7 64-bit Operating System for Easy Connectivity
2
C, SPI,

DPO5054 Summary of contents

Page 1

Mixed Signal Oscilloscopes MSO5000, DPO5000 Series Data Sheet Features & Benefits Key Performance Specifications 2 GHz, 1 GHz, 500 MHz, and 350 MHz Bandwidth Models GS/s Real-time Sample Rate on One or Two Channels and up to ...

Page 2

... MSO/DPO5000 Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design. Comprehensive Features Speed Every Stage ...

Page 3

... Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events. The advanced search and mark capability of the MSO/DPO5000 Series can even search for up to eight different events simultaneously and stop a live acquisition when it finds an event of interest, saving even more time. ® www.tektronix.com 3 ...

Page 4

... DDR memory bus analysis is also available. 4 www.tektronix.com Wave Inspector controls provide unprecedented efficiency in viewing, navigating, and analyzing waveform data. Zip through your long record by turning the outer pan control (1). Get from the beginning to end in seconds. See something of interest and want to see more details? Just turn the inner zoom control (2) ...

Page 5

... With the MSO/DPO5000 Series, you can choose infinite persistence or variable persistence, determining how long the previous waveform acquisitions stay on-screen. This allows you to determine how often an anomaly is occurring. www.tektronix.com 5 ...

Page 6

... The MSO5000 Series has redefined the way you view digital waveforms. One common problem with other mixed-signal oscilloscopes is determining 6 www.tektronix.com The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to make critical timing measurements on your digital waveforms. if data is a one or a zero when zoomed in far enough that the digital trace stays fl ...

Page 7

... Let the oscilloscope do it for you! Once you’ve set up a bus, the MSO/DPO5000 Series will decode each packet on the bus, and display the value in hex, binary, decimal (USB only) or ASCII (USB and RS-232/422/485/UART only) in the bus waveform. C, SPI, 2 www.tektronix.com 7 ...

Page 8

... Safe Operating Area measurement. Automated power measurements enable quick and accurate analysis of common power parameters. Advanced Analysis, Jitter, Eye Diagram, and Timing measurements. ...

Page 9

... PS-2 ports for keyboard and mouse are included for security-conscious applications that require the USB ports to be disabled. A standard removable hard disk drive makes customizing settings for different users easy as well as enables use in secure environments. www.tektronix.com 9 ...

Page 10

... MSO/DPO5000, DPO7000, and DPO/DSA/MSO70000 Series of Tektronix oscilloscopes. Floating licenses are available for many license-key enabled options. To order a floating version of an option license add “DPOFL-“ prefix to the option name. (e.g. DPOFL-ET3) Check www.tektronix.com for additional information about floating license options. ...

Page 11

... Windows Remote Desktop capability – connect directly to your oscilloscope and operate the user interface remotely through the built-in Remote Desktop. A second way to connect is through Tektronix OpenChoice software which makes use of the fast embedded bus, transferring waveform data directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers. Industry-standard protocols, such as TekVISA™ ...

Page 12

... Probe Loading 3 pF Vertical Resolution 1 bit 12 www.tektronix.com MSO5054 DPO5054 500 MHz 1 ns 700 ps ±1.5%, derated at 0.10%/°C above 30 °C Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, and 20 MHz 1 MΩ ±1%, 50 Ω ±1% 1 MΩ: 1 mV/div to 10 V/div 50 Ω ...

Page 13

... Channel-to-Channel 200 ps Skew (typical) Maximum Input Toggle 500 MHz at minimum input swing; higher toggle rates Rate can be achieved at higher amplitudes Mixed Signal Oscilloscopes — MSO5000, DPO5000 Series MSO5054 DPO5054 5 GS/s — — 400 GS/s 12.5M 25M 50M 125M 250 ps/div to 1000 s/div 2.5 ps/div – ...

Page 14

... SPI (Optional) Trigger data on SPI buses Mb/s RS-232/422/485/UART Trigger on Start Bit, End of Packet, Data, and Parity Error (Optional Mb/s 14 www.tektronix.com Mode Description USB (Optional) Low-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error. ...

Page 15

... Blackman-Harris, Gaussian, Flattop2, Tek Exponential Waveform Definition As an arbitrary math expression Filtering Functions User-definable filters. Users specify a filter containing the coefficients of the filter. Filter files provided Mask Function A function that generates a waveform database pixmap from a sample waveform. Sample count can be defined www.tektronix.com 15 ...

Page 16

... Data Sheet Software Software Description NI LabVIEW A fully interactive measurement software environment SignalExpress Tektronix optimized for the MSO/DPO5000 Series, enables Edition you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming ...

Page 17

... MSO/DPO5000 Family Product Description DPO5000 Models DPO5034 350 MHz, 5 GS/s, 12.5M record length, 4-channel digital phosphor oscilloscope DPO5054 500 MHz, 5 GS/s, 12.5M record length, 4-channel digital phosphor oscilloscope DPO5104 1 GHz, 10/5 GS/s (2/4 ch), 12.5M record length, 4-channel digital phosphor oscilloscope DPO5204 2 GHz, 10/5 GS/s (2/4 ch), 12 ...

Page 18

... Data Sheet Options Record Length Options Option MSO5034 DPO5034 MSO5054 DPO5054 Opt. 2RL 25M/Ch Opt. 5RL 50M/Ch Opt. 10RL 125M/Ch Software Options Option Description Opt. DDRA* DDR Memory Bus Analysis 1 Opt. DJA Jitter and Eye Analysis Tools – Advanced (DPOJET) Opt. ET3* ...

Page 19

... Recommended Accessories Probes Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tektronix.com/probes. Probe Description TPP0500 500 MHz, 10X TekVPI ® 3.9 pF input capacitance TPP1000 1 GHz, 10X TekVPI passive voltage probe with 3.9 pF ...

Page 20

... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...