ACPL-796J-000E Avago Technologies US Inc., ACPL-796J-000E Datasheet

no-image

ACPL-796J-000E

Manufacturer Part Number
ACPL-796J-000E
Description
Isolated Sigma-Delta Modulator, LF
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-796J-000E

Amplifier Type
Isolation
Number Of Circuits
1
Current - Input Bias
500nA
Voltage - Input Offset
3000µV
Current - Supply
14mA
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
16-SOIC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Current - Output / Channel
-
-3db Bandwidth
-
Slew Rate
-
Gain Bandwidth Product
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ACPL-796J
Optically Isolated Sigma-Delta Modulator
Data Sheet
Description
The ACPL-796J is a 1-bit, second-order sigma-delta (6')
modulator converts an analog input signal into a high-
speed data stream with galvanic isolation based on optical
coupling technology. The ACPL-796J operates from a 5 V
power supply with dynamic range of 80 dB with an appro-
priate digital filter. The differential inputs of ±200 mV (full
scale ±320 mV) are ideal for direct connection to shunt
resistors or other low-level signal sources in applications
such as motor phase current measurement.
The analog input is continuously sampled by means of
sigma-delta over-sampling using external clock, coupled
across the isolation barrier, which allows synchronous
operation with any digital controller. The signal infor-
mation is contained in the modulator data, as a density
of ones with data rate up to 20 MHz, and the data are
encoded and transmitted across the isolation boundary
where they are recovered and decoded into high-speed
data stream of digital ones and zeros. The original signal
information can be reconstructed with a digital filter. The
serial interface has a wide supply range of 3 V to 5.5 V.
Combined with superior optical coupling technology,
the modulator delivers high noise margins and excellent
immunity against isolation-mode transients. With 0.5 mm
minimum distance through insulation (DTI), the ACPL-796J
provides reliable double protection and high working
insulation voltage, which is suitable for fail-safe designs.
This outstanding isolation performance is superior to
alternatives including devices based on capacitive- or
magnetic-coupling with DTI in micro-meter range. Offered
in an SO-16 package, the isolated ADC delivers the reli-
ability, small size, superior isolation and over-temperature
performance motor drive designers need to accurately
measure current at much lower price compared to tradi-
tional current transducers.
The internal clock version modulators, HCPL-7860 (DIP-8/
gull wing surface mount package) and HCPL-786J (SO-16
package), are also available.
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
GN 1
V
V
Features
x 5 MHz to 20 MHz external clock input range
x 1-bit, second-order sigma-delta modulator
x 16 bits resolution no missing codes (12 bits ENOB)
x 74 dB minimum SNR
x 3.5 PV/°C maximum offset drift
x ±1% maximum gain error
x Internal reference voltage
x ±200 mV linear range with single 5 V supply
x 3 V to 5.5 V wide supply range for digital interface
x –40°C to +105°C operating temperature range
x SO-16 package
x 25 kV/Ps common-mode transient immunity
x Safety and regulatory approval (pending):
Applications
x Motor phase and rail current sensing
x Power inverter current and voltage sensing
x Industrial process control
x Data acquisition systems
x General purpose current and voltage sensing
x Traditional current transducer replacements
Functional Block Diagram
V
Figure 1.
IN
IN
+
1
IEC/EN/DIN EN 60747-5-5: 1230 Vpeak working
insulation voltage
UL 1577: 5000 Vrms/1min double protection rating
CSA: Component Acceptance Notice #5
MO U TOR/
V
REF
EN O ER
Σ−Δ
ETE TOR
O K
RIVER
E
HIE
HIE
RIVER
E
-
E O ER
V
M T
M KIN
GN 2
2

Related parts for ACPL-796J-000E

ACPL-796J-000E Summary of contents

Page 1

... The ACPL-796J is a 1-bit, second-order sigma-delta (6') modulator converts an analog input signal into a high- speed data stream with galvanic isolation based on optical coupling technology. The ACPL-796J operates from power supply with dynamic range with an appro- priate digital filter. The differential inputs of ±200 mV (full scale ± ...

Page 2

... To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example: ACPL-796J-560E to order product of Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-5 Safety Approval and RoHS compliance. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information. ...

Page 3

... Figure 3. 16-Lead Surface ount. ecommended Pb-Free I Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used. egulatory Information The ACPL-796J is pending for approvals by the following organizations 60747-5-5 Approved with Maximum Working Insulation Voltage V = 1230 Vpeak ...

Page 4

Table 60747-5-5 Insulation Characteristics Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms for rated mains voltage ≤ 450 V rms for ...

Page 5

Table 4. Insulation and Safety elated Specifications Parameter Symbol Minimum External Air Gap L(101) (External Clearance) Minimum External Tracking L(102) (External Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance CTI (Comparative Tracking Index) Isolation Group Table 5. Absolute aximum ...

Page 6

Table 7. lectrical Specifications Unless otherwise noted –40°C to +105° – (single-ended connection); tested with Sinc IN Parameter Symbol STATIC CHA ACT ISTICS Resolution 16 Integral Nonlinearity INL –15 –25 –25 Differential ...

Page 7

Table 8. Timing Specifications Unless otherwise noted –40°C to +105° Parameter Modulator Clock Input Frequency Data Delay After Rising Edge of [1] MCLKIN Notes: 1. Data changes at the clock rising edge so it can be ...

Page 8

Typical Performance Plots Unless otherwise noted 25° with Sinc filter, 256 decimation ratio MCLKIN = 20 MHz 30 MCLKIN = 10 MHz MCLKIN = 5 MHz -10 -20 -30 -40 ...

Page 9

T = +105° +85° +25° –40° -320 -240 -160 - (mV) IN Figure 11. I vs. DC input at ...

Page 10

... Analog Input The differential analog inputs of the ACPL-796J are im- plemented with a fully-differential, switched-capacitor circuit. The ACPL-796J accepts signal of ±200 mV (full scale ±320 mV), which is ideal for direct connection to shunt based current sensing or other low-level signal sources applications such as motor phase current measurement. ...

Page 11

... Other situations could cause transient voltages to the inputs include short circuit and overload conditions. The ACPL-796J is tested with DC voltage –2 V and 2- second transient voltage – the analog inputs and there is no latch-up or damage to the device. ...

Page 12

... A/D converter. With this conversion, the data rate of the word output is also 3 reduced (decimation). A Sinc filter is recommended to work together with the ACPL-796J. With a 10 MHz external ISOLATION ISOLATED BARRIER ...

Page 13

... SENSE the ACPL-796J through an RC anti-aliasing filter (R2 and C2). And finally, a clock is connected to the ACPL-796J and data are connected to the digital filter. Although the appli- cation circuit is relatively simple, a few recommendations should be followed to ensure optimal performance. ...

Page 14

Shunt esistors The current-sensing shunt resistor should have low re- sistance (to minimize power dissipation), low inductance (to minimize di/dt induced voltage spikes which could adversely affect operation), and reasonable tolerance (to maintain overall circuit accuracy). Choosing a particu- lar ...

Page 15

... PC board is also recommended. Shunt Connections The recommended method for connecting the isolated modulator to the shunt resistor is shown in Figure 18 the ACPL-796J is connected to the positive terminal of the shunt resistor, while V – is shorted to GND1, with the IN power-supply return path functioning as the sense line to the negative terminal of the current shunt ...

Page 16

... HV– Figure 0. Schematic for three conductor shunt connection. oltage Sensing The ACPL-796J can also be used to isolate signals with am- plitudes larger than its recommended input range with the use of a resistive voltage divider at its input. The only restrictions are that the impedance of the divider be rela- tively small (less than 1 k:) so that the input resistance (33 k:) and input bias current (0 ...