ACPL-796J Avago Technologies US Inc., ACPL-796J Datasheet
ACPL-796J
Specifications of ACPL-796J
Available stocks
Related parts for ACPL-796J
ACPL-796J Summary of contents
Page 1
... The ACPL-796J is a 1-bit, second-order sigma-delta (Σ-∆) modulator converts an analog input signal into a high- speed data stream with galvanic isolation based on optical coupling technology. The ACPL-796J operates from power supply with dynamic range with an appro- priate digital filter. The differential inputs of ±200 mV (full scale ± ...
Page 2
... To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example: ACPL-796J-560E to order product of Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-5 Safety Approval and RoHS compliance. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information. ...
Page 3
... NOTE: FLOATING LEAD PROTRUSION IS 0. mils) MAX. Figure 3. 16-Lead Surface Mount. Recommended Pb-Free IR Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used. Regulatory Information The ACPL-796J is pending for approvals by the following organizations: IEC/EN/DIN EN 60747-5-5 Approved with Maximum Working Insulation Voltage V = 1140 Vpeak. ...
Page 4
Table 3. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms for rated mains voltage ≤ 450 V rms for rated ...
Page 5
Table 4. Insulation and Safety Related Specifications Parameter Symbol Minimum External Air Gap L(101) (External Clearance) Minimum External Tracking L(102) (External Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance CTI (Comparative Tracking Index) Isolation Group Table 5. Absolute Maximum ...
Page 6
Table 7. Electrical Specifications Unless otherwise noted –40°C to +105° – (single-ended connection); tested with Sinc IN Parameter Symbol Min. STATIC CHARACTERISTICS Resolution 16 Integral Nonlinearity INL –15 –25 –25 Differential Nonlinearity ...
Page 7
Table 8. Timing Specifications Unless otherwise noted –40°C to +105° Parameter Modulator Clock Input Frequency Data Delay After Rising Edge of [1] MCLKIN Notes: 1. Data changes at the clock rising edge so it can be ...
Page 8
Typical Performance Plots Unless otherwise noted 25° with Sinc filter, 256 decimation ratio MCLKIN = 20 MHz 30 MCLKIN = 10 MHz MCLKIN = 5 MHz -10 -20 -30 -40 ...
Page 9
T = +105° +85° +25° –40° -320 -240 -160 - (mV) IN Figure 11 input ...
Page 10
... Analog Input The differential analog inputs of the ACPL-796J are im- plemented with a fully-differential, switched-capacitor circuit. The ACPL-796J accepts signal of ±200 mV (full scale ±320 mV), which is ideal for direct connection to shunt based current sensing or other low-level signal sources applications such as motor phase current measurement. ...
Page 11
... Other situations could cause transient voltages to the inputs include short circuit and overload conditions. The ACPL-796J is tested with DC voltage –2 V and 2- second transient voltage – the analog inputs and there is no latch-up or damage to the device. ...
Page 12
... A/D converter. With this conversion, the data rate of the word output is also 3 reduced (decimation). A Sinc filter is recommended to work together with the ACPL-796J. With a 10 MHz external ISOLATION ISOLATED BARRIER ...
Page 13
... SENSE the ACPL-796J through an RC anti-aliasing filter (R2 and C2). And finally, a clock is connected to the ACPL-796J and data are connected to the digital filter. Although the appli- cation circuit is relatively simple, a few recommendations should be followed to ensure optimal performance. ...
Page 14
Shunt Resistors The current-sensing shunt resistor should have low re- sistance (to minimize power dissipation), low inductance (to minimize di/dt induced voltage spikes which could adversely affect operation), and reasonable tolerance (to maintain overall circuit accuracy). Choosing a particu- lar ...
Page 15
... PC board is also recommended. Shunt Connections The recommended method for connecting the isolated modulator to the shunt resistor is shown in Figure 18 the ACPL-796J is connected to the positive terminal of the shunt resistor, while V – is shorted to GND1, with the IN power-supply return path functioning as the sense line to the negative terminal of the current shunt ...
Page 16
... HV– Figure 20. Schematic for three conductor shunt connection. Voltage Sensing The ACPL-796J can also be used to isolate signals with am- plitudes larger than its recommended input range with the use of a resistive voltage divider at its input. The only restrictions are that the impedance of the divider be rela- tively small (less than 1 kΩ ...