ABCU-5700RZ Avago Technologies US Inc., ABCU-5700RZ Datasheet

ROHS Gen2 Cuhead Module

ABCU-5700RZ

Manufacturer Part Number
ABCU-5700RZ
Description
ROHS Gen2 Cuhead Module
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ABCU-5700RZ

Data Rate
1.25Gbps
Applications
Ethernet
Voltage - Supply
3.3V
Connector Type
RJ45
Mounting Type
SFP
Data Rate Max
1.25Gbps
Supply Current
350mA
Supply Voltage
3.3V
Power Rating
1.1W
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Wavelength
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1976

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ABCU-5700RZ
Manufacturer:
AVG
Quantity:
71
Part Number:
ABCU-5700RZ
Manufacturer:
AVAGO
Quantity:
8 000
ABCU-5710RZ / ABCU-5700RZ
1000BASE-T 1.25 GBd Small Form Pluggable Low Voltage (3.3 V)
Electrical Transceiver over Category 5 Cable
Data Sheet
Description
The ABCU-5710RZ and ABCU-5700RZ electrical
transceivers from Avago Technologies offer full-duplex
throughput of 1000 Mbps by transporting data over
shielded and unshielded twisted pair category 5 cable
with 5-level PAM (Pulse Amplitude Modulation) signals.
The ABCU-5710RZ and ABCU-5700RZ differ only in
handling of RX_LOS signal functions, as explained
further on the following pages.
The Avago Technologies 1000BASE-T module takes
signals from both the twisted pair category 5 cable and
the SerDes interface. Pin count overhead between the
MAC and the PHY is minimized, and Gigabit Ethernet
operation is achieved with maximum space savings.
Module Diagrams
Figure 1 illustrates the major functional components of
the ABCU-5700/5710RZ. The 20-pin connection
diagram of module printed circuit board of the module
is shown in Figure 2. Figure 3 depicts the pin assignment
of the MDI (RJ45 jack).
Figure 6 depicts the external configuration and
dimensions of the module.
Features
• RoHS-6 Compliant (see Table 1)
• Designed for Industry-Standard, MSA Compliant
• Compatible with IEEE 802.3:2000
• Custom RJ-45 connector with integrated magnetics
• Link lengths at 1.25 Gbd: up to 100 m per IEEE802.3
• Low power, high performance 1.25 Gbd SerDes
• Single +3.3 V power supply operation
• Auto-negotiation per IEEE 802.3:2000 Clause 28
• Compatible to both shielded and unshielded twisted
• Two configurations:
• Rated for Commercial Temperature applications
Applications
• Switch to switch interface
• Switched backplane applications
• File server interface
Related Products
• AFBR-5710Z: Family of 850nm +3.3V SFP optical
• AFCT-5710Z: Family of 1310nm +3.3V SFP optical
Small Form Factor Pluggable (SFP) Ports
integrated in module
(Twisted Pair) and Clause 37 (1000BASE-X)
pair category 5 cable
ABCU-5700RZ: RX_LOS enabled
ABCU-5710RZ: RX_LOS disabled
(0° - 70° C)
transceivers for Gigabit Ethernet
transceivers for Gigabit Ethernet

Related parts for ABCU-5700RZ

ABCU-5700RZ Summary of contents

Page 1

... Mbps by transporting data over shielded and unshielded twisted pair category 5 cable with 5-level PAM (Pulse Amplitude Modulation) signals. The ABCU-5710RZ and ABCU-5700RZ differ only in handling of RX_LOS signal functions, as explained further on the following pages. The Avago Technologies 1000BASE-T module takes signals from both the twisted pair category 5 cable and the SerDes interface ...

Page 2

... The transceiver is compatible with an “ac- coupled” configuration and is internally terminated. Figure 1 depicts the functional diagram of the ABCU-5700/ 5710RZ. 100-ohm resistor shown at RX_LOS in Figure 1 RJ45 refers to ABCU-5710RZ configuration, not ABCU-5700RZ Magnetics Adapter configuration. Caution should be taken into account for the proper interconnection between the supporting Physical Layer integrated circuits and the ABCU-5700/5710RZ ...

Page 3

... V_SUPPLY 0 TX[0:9] HDMP- PROTOCOL IC 1636A RX[0:9] REF CLK 4.7 K 4.7 K Figure 4. Typical Application Configuration for ABCU-5710RZ 0.1 µ 0.1 µF 10 µF SFP MODULE HOST BOARD Note: Inductors must have less than 1ohm series resistance per MSA Figure 5. MSA Recommended Power Supply Filter ...

Page 4

... To protect the transceiver important to use normal ESD handling precautions. These precautions include using grounded wrist straps, work benches, and floor mats in ESD controlled areas. The ESD sensitivity of the ABCU-5700/5710RZ is compatible with typical industry production environments. The second condition is static discharges to the exterior of the host equipment chassis after installation ...

Page 5

... Connecting the module to a non-approved 1000BaseT module, operating above the recommended absolute maximum conditions or operating the ABCU-5710RZ in a manner inconsistent with its design and function may result in hazardous radiation exposure and may be considered an act of modifying or manufacturing an electrical module product ...

Page 6

... Mod-Def 2 is data line of two wire serial interface for optional serial ID 4. LOS (Loss of Signal) operation on the 1000BaseT SFP is different than for optical SFP applications. For ABCU-5700RZ, RX_LOS signal is a 1000BASE-T linkup/link-down indicator and not a peak (AC) or voltage (DC) detector. For ABCU-5710RZ, RX_LOS is not used and is always tied to ground via 100-ohm resistor. 5. RD-/+: These are the differential receiver outputs. They are ac coupled 100 Ω ...

Page 7

Absolute Maximum Ratings Parameter Storage Temperature Case Temperature Relative Humidity Module Supply Voltage Data/Control Input Voltage Sense Output Current - LOS Sense Output Current - MOD-DEF2 Recommended Operating Conditions Parameter Case Temperature Module Supply Voltage Data Rate Transceiver Electrical Characteristics ...

Page 8

Transmitter and Receiver Electrical Characteristics ( °C to +70 °C, V T,R = 3.3 V ± Parameter Data Input: Transmitter Differential Input Voltage (TD +/-) Data Output: Receiver Differential Output Voltage (RD +/-) Receive ...

Page 9

V > 3. POWER SAVING (TX_DISABLE) TRANSMITTED SIGNAL (AUTO-NEGOTIATION BEGINS) t-init: MODULE HOT-PLUGGED OR VOLTAGE APPLIED AFTER INSERTION, WHEN TX_DISABLE IS NEGATED V > 3. TX_DISABLE TRANSMITTED SIGNAL (AUTO-NEGOTIATION BEGINS) t-init: VOLTAGE APPLIED WHEN TX_DISABLE IS ...

Page 10

... Notes: 1. For ABCU-5700RZ, Address 47 is ASCII 0 (30h). For ABCU-5710RZ, Address 47 is ASCII 1 (31h). 2. Addresses 63 and 95 are check sums. Address 63 is the check sum for bytes 0-62 and address 95 is the check sum for bytes 64-94. 3. Address 68-83 specify a unique identifier. ...

Page 11

Internal ASIC Registers The ASIC (or “PHY”, for Physical Layer IC) in the transceiver module contains 32 registers. Each register contains 16 bits. The registers are summarized in table 11 and detailed in table 12 through 28. Each bit is ...

Page 12

Table 5. Register 0 (Control) Bit Name 0.15 Reset R/W 0.14 Loopback R/W 0.13 Speed Selection (LSB) R/W 0.12 Auto-Negotiation Enable R/W 0.11 Power Down R/W 0.10 Isolate R/W 0.9 Restart Auto-Negotiation R/W/SC 0.8 Duplex Mode R/W 0.7 Collision Test ...

Page 13

Table 6. Register 1 (Status) Bit Name 1.15:9 N/A to SFP Module RO 1.8 Extended Status RO 1.7 N/A to SFP Module RO 1.6 MF Preamble Suppression RO 1.5 Auto-Negotiation RO Complete 1.4 Remote Fault RO/LH 1.3 Auto-Negotiation Ability RO ...

Page 14

Table 7. Register 4 (Auto-Negotiation Advertisement) Bit Name 4.15:14 N/A to SFP Module R/W 4.13 Remote Fault R/W 4.12 N/A to SFP Module R/W 4.11:10 PAUSE Encoding R/W 4.9:5 N/A to SFP Module R/W 4.4:0 IEEE 802.3 Selector Field RO ...

Page 15

Table 8. Register 5 (Auto-Negotiation Link Partner Ability) Bit Name 5.15 Next Page RO 5.14 Acknowledge RO 5.13 Remote Fault RO 5.12 N/A to SFP Module RO 5.11:10 PAUSE Encoding RO 5.9:5 N/A to SFP Module RO 5.4:0 IEEE 802.3 ...

Page 16

Table 10. Register 7 (Auto-Negotiation Next Page Transmit Register) Bit Name 7.15 Next Page R/W 7.14 N/A to SFP Module RO 7.13 Message Page R/W 7.12 Acknowledge 2 R/W 7.11 Toggle RO 7.10:0 Message/Unformatted R/W Code Field Table 11. Register ...

Page 17

Table 12. Register 9 (MASTER-SLAVE Control) Bit Name 9.15:13 Transmitter Test Mode R/W 9.12 MASTER-SLAVE Manual R/W Config Enable 9.11 MASTER-SLAVE Config R/W Value 9.10 Port Type R/W 9.9 1000BASE-T Full Duplex R/W 9.8 1000BASE-T Half Duplex R/W 9.7:0 N/A ...

Page 18

Table 13. Register 10 (MASTER-SLAVE Status) Bit Name 10.15 MASTER-SLAVE RO/LH/SC Configuration Fault 10.14 MASTER-SLAVE RO Configuration Resolution 10.13 Local Receiver Status RO 10.12 Remote Receiver Status RO 10.11 Link Partner Full Duplex RO 10.10 Link Partner Half Duplex RO ...

Page 19

Table 14. Register 16 (Extended Control 1) Bit Name 16.15:7 N/A to SFP Module R/W 16.6:5 MDI Crossover Mode R/W 16.4:0 N/A to SFP Module R/W 19 Description Hardware Reset 000000000 00 = Manual MDI 11 configuration 01 = Manual ...

Page 20

Table 15. Register 17 (Extended Status 1) Bit Name 17.15:14 Speed RO 17.13 Duplex RO 17.12 Page Received RO/LH 17.11 Speed and Duplex RO Resolved 17.10 Link RO 17.9:7 Cable Length RO 17.6 MDI Crossover Status RO 17.5:4 N/A to ...

Page 21

Table 16. Register 20 (Extended Control 2) Bit Name 20.15 Link down on no idles RO 20.14:4 N/A to SFP Module R/W 20.3 Clause 37 Auto- R/W Negotiation Enable 20.2:0 N/A to SFP Module R/W Table 17. Register 21 (Receive ...

Page 22

Table 19. Register 26 (Extended Control 3) Bit Name 26.15:8 N/A to SFP Module RO 26.7:3 N/A to SFP Module R/W 26.2:0 RD+/- Output Amplitude R/W Table 20. Register 27 (Extended Status 2) Bit Name 27.15:13 N/A to SFP Module ...

Page 23

Table 21. Register 28 (Cable Diagnostic 2) Bit Name 28.15 Enable Cable Diagnostic R/W Test 28.14:13 Status RO 28.12:8 Reflected Magnitude RO 28.7:0 Distance RO 23 Description Hardware Reset 1 = Enable test disable test 11 = ...

Page 24

Figure 7a. Module Drawing 24 66.04 - 71.12 13.40 0.10 51.40 1.00 PCB 1.00 0.10 2.25 0.10 2.67 34.30 41.80 0.15 8.50 0.10 9.20 0.10 ...

Page 25

CAGE ASSEMBLY BEZEL NOTE: DIMENSIONS IN MILLIMETERS Figure 7b. Assembly Drawing 25 13.80 MAX 1.70 0.90 3.50 0.30 5.94 0.20 13.49 0.30 2.58 0.20 22.11 0.30 SFP MSA RECOMMENDED BEZEL PC BOARD 15.25 0.10 1.56 0.20 10.40 ...

Page 26

NOTE: DIMENSIONS IN MILLIMETERS Figure 7c. Angled Application 26 70~ 25.30 22.84 3.83 2.06 ...

Page 27

Figure 7d. SFP Host Board Mechanical Layout 27 ...

Page 28

For product information and a complete list of distributors, please go to our web site: Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies, Limited in the United States and other countries. Data subject to change. Copyright ...

Related keywords