H5BR-B-AC100-240 Omron, H5BR-B-AC100-240 Datasheet - Page 6

no-image

H5BR-B-AC100-240

Manufacturer Part Number
H5BR-B-AC100-240
Description
TIMER DIGITAL LCD
Manufacturer
Omron
Series
H5BRr
Datasheet

Specifications of H5BR-B-AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage
Lead Free Status / Rohs Status
Supplier Unconfirmed
Dimensions
H5BR
1. The batch count present value remains
2. When the batch count set value is 0,
3. When the batch count present value
4. The batch count present value and
Unit: mm (inch)
Output mode F: Cumulative (Timer does not reset when power comes on.)
Batch count reset
at 0 while the batch count reset is ON.
the batch count will proceed, but there
will be no output.
exceeds 9999, it returns to 0.
output are not affected by the RESET
key or reset input.
BATCH COUNTER OPERATION
Batch count set
present value 0
TIMER
Timing
diagram
Batch output
Batch count
value
Control output
UP
DOWN
Start signal
Set value
Set value
Power
Reset
Gate
0
0
(2.83)
72
5. When power is interrupted and the
6. When a batch count set value greater
7. If, after the output has gone ON, the set
batch count output is ON, the output
will be ON when power returns.
than the present value is changed to a
set value less than the present value,
the output will go ON.
value is changed to a set value that is
(2.83)
72
6
(0.24)
6
Timing begins on the leading edge of the
start signal. The control output is
energized when the cumulative elapsed
time of the start signal is equal to the
preset time. The output is sustained until
power is interrupted or a reset signal is
applied.
The batch count output holds until reset
by the batch count reset. The present
value of the batch count advances
continuously.
8. When utilizing latching outputs in the
greater than the present value, the
output will remain ON.
repeat cycle modes (B and B1), the
number of completed timing is double
the number of outputs. To control the
number of outputs, set the batch count
set value at double the desired number
of outputs.
(3.94)
100
M3.5 terminal screw,
effective length: 6 mm (0.24)
(2.66)
67.6
H5BR