H3CR-A8E AC/DC24-48 Omron, H3CR-A8E AC/DC24-48 Datasheet - Page 2

SOLID STATE TIMER-ANALOG SET

H3CR-A8E AC/DC24-48

Manufacturer Part Number
H3CR-A8E AC/DC24-48
Description
SOLID STATE TIMER-ANALOG SET
Manufacturer
Omron
Series
H3CR-Ar
Type
Solid State Multi-Functional Timerr

Specifications of H3CR-A8E AC/DC24-48

Rohs Compliant
YES
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 48VAC, 12 ~ 48VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 sec to 300 hrs
Supply Voltage
24 V to 48 V
Accuracy
+/- 0.2 %
Operating Temperature Range
- 10 C to + 55 C
Product
Analog Timer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A8E-AC/DC24-48
H3CRA8EACDC2448
Z2381
Ordering Information
■ List of Models
11-pin Models
8-pin Models
Note: 1. Specify both the model number and supply voltage when ordering.
Contact
Transistor
(Photocoupler)
Contact
Transistor
(Photocoupler)
Time-limit contact and
instantaneous contact
2. The operating modes are as follows
Output
Output
Example: H3CR-A 100-240AC/100-125DC
A:
B:
B2:
C:
ON-delay
Flicker OFF start
Flicker ON start
Signal ON/OFF-delay
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
24 to 48 VAC (50/60 Hz)/
12 to 48 VDC
100 to 240 VAC (50/60 Hz)/
100 to 125 VDC
24 to 48 VAC/VDC (50/60 Hz)
Supply voltage
Supply voltage
D: Signal OFF-delay
E: Interval
G: Signal ON/OFF-delay
J: One-shot
Supply voltage
No-voltage input
Voltage input
No-voltage input
No-input available 0.05 s to 300 h
Input type
Input type
0.05 s to 300 h
0.1 s to 600 h
0.05 s to 300 h
0.1 s to 600 h
0.05 s to 300 h
Time range
Time range
Six multi-modes: A, B,
B2, C, D, E
Dual-modes: G, J
Six multi-modes: A, B,
B2, C, D, E
Four multi-modes: A,
B2, E, J
(Power supply start)
Operating mode
Operating mode
(See note 2)
(See note 2)
H3CR-A
H3CR-A-300
H3CR-AP
H3CR-A-301
H3CR-AS
H3CR-A8
H3CR-A8-301
H3CR-A8S
H3CR-A8E
H3CR-A
(See note 1.)
(See note 1.)
Model
Model
2

Related parts for H3CR-A8E AC/DC24-48