H3CR-A8E AC/DC24-48 Omron, H3CR-A8E AC/DC24-48 Datasheet - Page 16

SOLID STATE TIMER-ANALOG SET

H3CR-A8E AC/DC24-48

Manufacturer Part Number
H3CR-A8E AC/DC24-48
Description
SOLID STATE TIMER-ANALOG SET
Manufacturer
Omron
Series
H3CR-Ar
Type
Solid State Multi-Functional Timerr

Specifications of H3CR-A8E AC/DC24-48

Rohs Compliant
YES
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 48VAC, 12 ~ 48VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 sec to 300 hrs
Supply Voltage
24 V to 48 V
Accuracy
+/- 0.2 %
Operating Temperature Range
- 10 C to + 55 C
Product
Analog Timer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A8E-AC/DC24-48
H3CRA8EACDC2448
Z2381
Application Examples (H3CR-A)
A Mode: ON-delay
ON-delay operation (A mode) is a basic mode.
1. Power-ON Start/Power-OFF Reset
The Power-ON start/Power-OFF reset operation is a standard
operating method.
2. Signal Start/Signal Reset
The Signal start/Signal reset operation is useful for remote control of
the Timer.
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Power (2 and 10)
Power indicator
Power (2 and 10)
Start (2 and 6)
Reset (2 and 7)
Externally short-circuited
Reset (2 and 7)
Power indicator
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Start signal (remote control possible)
Reset signal
(remote control possible)
Lit
(Power continuously supplied)
Flashing
Flashing
t
t
Power
supply
Power
supply
Lit
Lit
3. Control of Integrated Time with Gate
With a gate signal, the Power-ON start operation and Signal start
operation can be controlled (the operation can be interrupted).
B/B2 Mode: Flicker
The flicker operation in the B and B2 modes can be effectively
applied to lamp or buzzer (ON and OFF) alarms or the monitoring of
an intermittent operation with a display.
1. Power-ON Start/Power-OFF Reset (in B
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Signal
Mode)
Externally short-circuited
Power (2 and 10)
Power (2 and 10)
Power indicator
Power indicator
Start (2 and 6)
Gate (2 and 5)
Start (2 and 6)
Gate signal (The operation is interrupted with the
gate signal if the Timer detects an abnormal signal.)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Externally
short-circuited
t
1
Flashing
Power
supply
Power
supply
Flashing
t
2
t
1
+ t
H3CR-A
2
: set time
Lit
16