E53-C3D Omron, E53-C3D Datasheet - Page 4

no-image

E53-C3D

Manufacturer Part Number
E53-C3D
Description
0-20 CURRENT OUTPUT ES100&E5_J
Manufacturer
Omron
Datasheet

Specifications of E53-C3D

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E53C3D
206
E5 J
Note:
Note:
Specifications,
Materials
Mounting
Weight
Connections
Enclosure
ratings
Approvals
Ambient
temperature
Humidity
Insulation resistance
Dielectric strength
Vibration
Shock
Part number
Heater current
Dielectric strength
Vibration resistance
Weight
Accessories included
Protocol
Transmission method
Maximum cable length
Synchronization method
Baud rate
Transmission code
Write to temperature controller
Read from temperature controller Process value, output value, set point, alarm value, heater current value, initial status, proportional
System limits
CURRENT TRANSFORMERS FOR E5AJ, E5EJ, E5CJ 2HB-F
COMMUNICATIONS FOR E5AJ, E5EJ
Optional NEMA 4 panel covers are available for E5–J controllers:
Y92A-96N for E5AJ, Y92A-49N for E5EJ, and Y92A-48N for E5CJ
If E5AJ is in ON/OFF control mode or PID control mode with fuzzy self-tuning, an undefined error will result if the proportional
band, integral time, or derivative time command is transmitted.
Controller
Mounting hardware
Front panel
Rear case
Terminals
UL
CSA
Operating
Storage
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
E54-CT1
Maximum 50 A continuous service, single-phase
1,000 VAC
50 Hz (approx. 10 G)
11.5 g (0.41 oz.)
RS-232C
4-wire half duplex
15 m (49.2 ft)
Start-stop synchronization (asynchronous method)
1,200/2,400/4,800/9,600/19,200 bps
ASCII (7 bits)
Set point, alarm value, remote/local selection, proportional band, integral time, rate time (see note)
band, reset time, rate time, error codes, etc. (see note)
Peer to peer only
continued
Plastic case
Fits 1/4 DIN panel cutouts, Fits 1/8 DIN panel
includes two panel
mounting brackets
Approx. 360 g (12.7 oz.)
Brackets 65 g (2.3 oz.)
Plated steel screw terminals mounted on rear of unit
IEC IP54, NEMA 4 with optional Y92A covers (see note)
IEC IP20
IEC IP00
Recognized, File number E68481
Certified, File number LR59623
-10 to 55 C (14 to 131 F)
-25 to 65 C (-13 to 149 F)
35 to 85% RH
20 M minimum at 500 VDC, measured with an output unit installed
2,000 VAC, 50/60 Hz for 1 minutes between terminals of different polarities
10 to 55 Hz, 19.6 m/s
10 to 55 Hz, 9.8 m/s
294 m/s
196 m/s
2
2
(30 G) in 6 directions, 3 times each
(20 G) in 6 directions, 3 times each
2
(1 G) in X, Y, and Z directions for 10 minutes
2
(2 G) in X, Y, and Z directions for 2 hours each
RS-422
4-wire half duplex
500 m (1,640 ft)
A maximum of 32 controllers can be connected to one host
computer in serial communication
cutouts, includes two
panel mounting brackets
Approx. 280 g (9.9 oz.)
Brackets 65 g (2.3 oz.)
E54-CT3
50 g (1.8 oz.)
2 contacts, 2 plugs
Fits 1/16 DIN panel cutouts, includes
Y92F-30 panel mounting adapter
Approx. 170 g (6.0 oz.)
Adapter 10 g (0.35 oz.)
RS-485
2-wire half-duplex
500 m (1,640 ft)
E5 J

Related parts for E53-C3D